Cockpit Additional Electrical Supply Always Operate


TASK 25-18-51-810-801-A
Cockpit Additional Electrical Supply Always Operate


1. Possible Causes

2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
VOLTMETER - TRUE RMS AC VOLTAGE MEASURING
 B. Referenced Information
REFERENCE
DESIGNATION
ASM 251800
AMM 25-18-51-000-001
Removal of the Static Inverter
3. Fault Confirmation
Subtask 25-18-51-865-050-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUPILOTS OUTLETS/STAT INV1NAK25
Subtask 25-18-51-710-050-A ** ON A/C NOT FOR ALL
B. Test
   (1) Disconnect all devices from captain outlet (5NA) and/or (4NA).
   (2) Connect the VOLTMETER - TRUE RMS AC VOLTAGE MEASURING to the electrical test plug and make sure that there is no voltage 115VAC.
4. Fault Isolation
Subtask 25-18-51-865-051-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUPILOTS OUTLETS/STAT INV1NAK25
Subtask 25-18-51-810-050-A ** ON A/C NOT FOR ALL
B. If there is confirmation of the fault:
   (1) remove the static inverter (3NA) AMM 25-18-51-000-001.
  • Do a check of the voltage of the pin AE.
     (a) If ground is present replace the Captain outlet (5NA) and/or First Officer (4NA).
   (2) If the fault continues:
  • Connect on outlet 4NA and/or 5NA one equipement.
     (a) Check there is no ground on pin AE.
  • If the ground is absent replace the oulets 4NA and 5NA.
     (b) Check the wiring ASM 251800
       1 If the wiring is not correct:
  • repair it.
   (3) If the fault continues:
  • Check there is no ground on pin AE.
     (a) If the is presence of ground replace the static inverter (3NA).
5. Close-up
Subtask 25-18-51-942-050-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.