Vertical Electrical Control of the First Officer Seat Inoperative
TASK 25-11-00-810-802-A
Vertical Electrical Control of the First Officer Seat Inoperative
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 25-11-00-710-051-A
Subtask 25-11-00-810-051-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:59 UTC
Vertical Electrical Control of the First Officer Seat Inoperative
1. Possible Causes
- SEAT-F/O [4MS]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 25-11-00-710-001 | Operational Test of the Captain and First Officer Seats |
| AMM 25-11-51-000-001 | Removal of the Captain/First Officer Seat |
| AMM 25-11-51-400-001 | Installation of the Captain/First Officer Seat |
Subtask 25-11-00-710-051-A
A. Test
(1) Do the operational test of the Captain and First Officer seats (3MS, 4MS) AMM 25-11-00-710-001.
4. Fault Isolation(1) Do the operational test of the Captain and First Officer seats (3MS, 4MS) AMM 25-11-00-710-001.
NOTE: Do the test for the First Officer seat only.
Subtask 25-11-00-810-051-A
A. If during the operational test the vertical electrical control of the First Officer seat is inoperative:
- replace the SEAT-F/O [4MS] AMM 25-11-51-000-001 and AMM 25-11-51-400-001.