Refueling not Possible
TASK 24-67-00-810-801-A
Refueling not Possible
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-67-00-860-050-A
Subtask 24-67-00-865-050-A
Subtask 24-67-00-860-051-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:59 UTC
Refueling not Possible
1. Possible Causes
RELAY - REFLNG NORM/BAT (5PR) RELAY - REFLNG BUS 501PP CTL (8PR) - CNTOR-DC SVCE BUS GND SPLY [3PX]
- CNTOR-DC SVCE BUS NORM SPLY [8PN]
- CTL PNL-REFUEL/DEFUEL [800VU]
- wiring
- C/B-ELEC/REFLNG/ON/BAT [1PR]
- C/B-ELEC/RFL/SPLY/LOGIC [4PR]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-00-00-810-803-A | Circuit Breaker Tripped and/or C/B TRIPPED Warning |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 24-43-55-000-001 | Removal of the DC Service Bus Ground Supply Contactor |
| AMM 24-43-55-400-001 | Installation of the DC Service Bus Ground Supply Contactor |
| AMM 24-61-55-000-001 | Removal of the DC Service Bus Normal Supply Contactor |
| AMM 24-61-55-400-001 | Installation of the DC Service Bus Normal Supply Contactor |
| ASM 246701 | |
| AMM 28-25-55-000-001 | Removal of the Refuel Panel |
| AMM 28-25-55-400-001 | Installation of the Refuel Panel |
Subtask 24-67-00-860-050-A
A. Job Set-up
(1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
Subtask 24-67-00-700-050-A (1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
B. Test
No applicable, the fault is evident.
4. Fault IsolationNo applicable, the fault is evident.
Subtask 24-67-00-865-050-A
A. Table of the circuit breakers used in this procedure:
Subtask 24-67-00-810-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | ELEC/RFL/SPLY/LOGIC | 4PR | U29 |
| 122VU | ELEC/REFLNG/ON/BAT | 1PR | U28 |
B. If the refueling is not possible:
Subtask 24-67-00-710-050-A - Do a check of the battery 1 voltage.
- Do a check of the status of the circuit breakers (1PR) and (4PR).
- Replace the
RELAY - REFLNG NORM/BAT (5PR) andRELAY - REFLNG BUS 501PP CTL (8PR) .
- Replace the CNTOR-DC SVCE BUS GND SPLY [3PX] AMM 24-43-55-000-001 and AMM 24-43-55-400-001.
- Replace the CNTOR-DC SVCE BUS NORM SPLY [8PN] AMM 24-61-55-000-001 and AMM 24-61-55-400-001.
- Replace the CTL PNL-REFUEL/DEFUEL [800VU] AMM 28-25-55-000-001 and AMM 28-25-55-400-001.
- Do a check and repair the wiring between respectively:
. the circuit breaker (1PR) and the pin A/C1 of the relay (5PR)
. the circuit breaker (4PR) and the pins A/X1 and A/A1 of the relay (5PR)
. the pin A/X2 of the relay (5PR) and the ground, through the contactors (3PX and 8PN), the switch (10PR) or the relay (11PR), and the microswitch (20QU)
. the pin A/C2 of the relay (5PR) and the pins A/A1, A/C1 and A/X1 of the relay (8PR)
. the pin A/A2 of the relay (8PR) and the terminal block
. the pin A/C2 of the relay (8PR) and the terminal block
. the pin A/X2 of the relay (8PR) and the ground ASM 246701.
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace the C/B-ELEC/REFLNG/ON/BAT [1PR] .
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace the C/B-ELEC/RFL/SPLY/LOGIC [4PR] .
C. Do this test.
(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do a refueling to make sure that the fault does not continue.
5. Close-up(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do a refueling to make sure that the fault does not continue.
Subtask 24-67-00-860-051-A
A. Put the aircraft back to its initial configuration.
(1) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
(1) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.