W DOC AIRBUS | TSM A320F

Refueling not Possible


TASK 24-67-00-810-801-A
Refueling not Possible


1. Possible Causes
  • RELAY - REFLNG NORM/BAT (5PR)
  • RELAY - REFLNG BUS 501PP CTL (8PR)
  • CNTOR-DC SVCE BUS GND SPLY [3PX]
  • CNTOR-DC SVCE BUS NORM SPLY [8PN]
  • CTL PNL-REFUEL/DEFUEL [800VU]
  • wiring
  • C/B-ELEC/REFLNG/ON/BAT [1PR]
  • C/B-ELEC/RFL/SPLY/LOGIC [4PR]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 24-00-00-810-803-A
Circuit Breaker Tripped and/or C/B TRIPPED Warning
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
AMM 24-43-55-000-001
Removal of the DC Service Bus Ground Supply Contactor
AMM 24-43-55-400-001
Installation of the DC Service Bus Ground Supply Contactor
AMM 24-61-55-000-001
Removal of the DC Service Bus Normal Supply Contactor
AMM 24-61-55-400-001
Installation of the DC Service Bus Normal Supply Contactor
ASM 246701
AMM 28-25-55-000-001
Removal of the Refuel Panel
AMM 28-25-55-400-001
Installation of the Refuel Panel
3. Fault Confirmation
Subtask 24-67-00-860-050-A
A. Job Set-up
   (1) Aircraft Maintenance Configuration
     (a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
Subtask 24-67-00-700-050-A
B. Test
No applicable, the fault is evident.
4. Fault Isolation
Subtask 24-67-00-865-050-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VUELEC/RFL/SPLY/LOGIC4PRU29
122VUELEC/REFLNG/ON/BAT1PRU28
Subtask 24-67-00-810-050-A
B. If the refueling is not possible:
  • Do a check of the battery 1 voltage.
   (1) If the voltage is correct:
  • Do a check of the status of the circuit breakers (1PR) and (4PR).
     (a) If the circuit breakers are closed:
  • Replace the RELAY - REFLNG NORM/BAT (5PR) and RELAY - REFLNG BUS 501PP CTL (8PR).
       1 If the fault continues:
       2 If the fault continues:
       3 If the fault continues:
       4 If the fault continues:
  • Do a check and repair the wiring between respectively:
    . the circuit breaker (1PR) and the pin A/C1 of the relay (5PR)
    . the circuit breaker (4PR) and the pins A/X1 and A/A1 of the relay (5PR)
    . the pin A/X2 of the relay (5PR) and the ground, through the contactors (3PX and 8PN), the switch (10PR) or the relay (11PR), and the microswitch (20QU)
    . the pin A/C2 of the relay (5PR) and the pins A/A1, A/C1 and A/X1 of the relay (8PR)
    . the pin A/A2 of the relay (8PR) and the terminal block
    . the pin A/C2 of the relay (8PR) and the terminal block
    . the pin A/X2 of the relay (8PR) and the ground ASM 246701.
     (b) If the circuit breaker (1PR) is open:
       1 If the fault continues:
  • Replace the C/B-ELEC/REFLNG/ON/BAT [1PR] .
     (c) If the circuit breaker (4PR) is open:
       1 If the fault continues:
  • Replace the C/B-ELEC/RFL/SPLY/LOGIC [4PR] .
Subtask 24-67-00-710-050-A
C. Do this test.
   (1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
   (2) Do a refueling to make sure that the fault does not continue.
5. Close-up
Subtask 24-67-00-860-051-A
A. Put the aircraft back to its initial configuration.
   (1) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
[Rev.8 from Aug 2018] 2026.04.04 04:26:59 UTC