Loss of the 601PP and 602PP busbars in Normal Configuration


TASK 24-61-00-810-801-A
Loss of the 601PP and 602PP busbars in Normal Configuration


1. Possible Causes
  • wiring
  • C/B-DC SVCE/602PP/SPLY [7PN]
  • CNTOR-DC SVCE BUS NORM SPLY [8PN]
  • CNTOR-DC SVCE BUS GND SPLY [3PX]
  • C/B-ELEC/DC/SVCE/BUS [5PN]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 24-00-00-810-803-A
Circuit Breaker Tripped and/or C/B TRIPPED Warning
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
ASM 244301
AMM 24-43-55-000-001
Removal of the DC Service Bus Ground Supply Contactor
AMM 24-43-55-400-001
Installation of the DC Service Bus Ground Supply Contactor
ASM 246101
AMM 24-61-55-000-001
Removal of the DC Service Bus Normal Supply Contactor
AMM 24-61-55-400-001
Installation of the DC Service Bus Normal Supply Contactor
3. Fault Confirmation
Subtask 24-61-00-860-050-A
A. Job Set-UP
   (1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
Subtask 24-61-00-710-050-A
B. Test
ACTION
RESULT
1.On the overhead panel 25VU:
  • put the INT LT/DOME switch in the BRT position

  • the CAPT dome lights do not come on.
4. Fault Isolation
Subtask 24-61-00-865-050-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VUELEC/DC/SVCE/BUS5PNX24
124VUDC SVCE/602PP/SPLY7PNBD01
Subtask 24-61-00-810-050-A
B. If the test confirms the fault:
  • Do a check of the status of the circuit breaker (7PN).
   (1) If the circuit breaker is closed:
  • Do a check for 28VDC on the pin F of the contactor (8PN) ASM 246101.
     (a) If there is no 28VDC:
  • Do a check of the wiring between the circuit breaker (7PN) and the contactor (8PN) ASM 246101.
       1 If there is no continuity:
  • Repair the wiring.
       2 If there is continuity:
  • Replace the C/B-DC SVCE/602PP/SPLY [7PN] .
     (b) If there is 28VBC:
  • Do a check for 28VDC on the pin 3 of the contactor (8PN) ASM 246101.
       1 If there is 28VDC:
         a If the fault continues:
  • Do a check and repair the wiring between A/E of the contactor (8PN) and the busbars 601PP and 602PP ASM 244301.
       2 If there is no 28VDC:
  • Do a check of the wiring between the circuit breaker (5PN) and the pin 3 of the contactor (8PN) ASM 246101.
         a If there is no continuity:
  • Repair the wiring.
         b If there is continuity:
         c If the fault continues:
  • Replace the C/B-ELEC/DC/SVCE/BUS [5PN] .
   (2) If the circuit breaker is open:
     (a) If the fault continues:
  • Replace the C/B-DC SVCE/602PP/SPLY [7PN] .
Subtask 24-61-00-710-051-A
C. Do the test given in Para. 3 and make sure that the CAPT dome lights come on.
5. Close-up
Subtask 24-61-00-860-051-A
A. Put the aircraft back to its initial configuration.
   (1) On the overhead panel 25VU, put the INT LT/DOME switch in the OFF position.
   (2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.