Unwanted DC BUS 2 FAULT Warning
TASK 24-60-00-810-807-A
Unwanted DC BUS 2 FAULT Warning
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-60-00-860-060-A
Subtask 24-60-00-865-062-A
Subtask 24-60-00-860-061-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:58 UTC
Unwanted DC BUS 2 FAULT Warning
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-00-00-810-803-A | Circuit Breaker Tripped and/or C/B TRIPPED Warning |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| ASM 246101 | |
| ASM 315408 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 31-60-00-860-002 | EIS Stop Procedure |
Subtask 24-60-00-860-060-A
A. Job Set-up
(1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
Subtask 24-60-00-865-052-A (1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 24-60-00-710-062-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | EIS/SDAC1 AND 2/BUS2/28VDC | 44WV | P03 |
| 124VU | 202PP/SPLY | 1PN2 | BG01 |
C. Do this Test:
4. Fault Isolation| ACTION | RESULT |
|---|---|
On the ECAM control panel:
| On the lower ECAM DU, on the ELEC page:
|
On the upper ECAM DU:
|
Subtask 24-60-00-865-062-A
A. Table of the circuit breakers used in this procedure:
Subtask 24-60-00-810-056-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | EIS/SDAC1 AND 2/BUS2/28VDC | 44WV | P03 |
| 124VU | 202PP/SPLY | 1PN2 | BG01 |
B. If the test confirms the fault:
Subtask 24-60-00-810-056-B ** ON A/C NOT FOR ALL - Do a check of the status of the EIS/SDAC1 & 2/BUS2/28VDC circuit breaker (44WV).
- Remove SDAC1 AMM 31-55-34-000-001.
- Replace SDAC-1 [1WV1] AMM 31-55-34-400-001.
- Install SDAC1 AMM 31-55-34-400-001.
- Remove SDAC2 AMM 31-55-34-000-001.
- Replace SDAC-2 [1WV2] AMM 31-55-34-400-001.
- Do a check and repair the wiring between:
. 28VDC BUS 2 (202PP) and the first branch point, the EIS/SDAC1 & 2/BUS2/28VDC circuit breaker (44WV) included
. 28VDC BUS 2 (202PP) and pin E of the TR2 contactor (5PU2), the EIS/SDAC1 & 2/BUS2/28VDC circuit breaker (1PN2) included, ASM 315408 and ASM 246101. - Install SDAC2 AMM 31-55-34-400-001.
- Do the trouble shooting procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace C/B-EIS/SDAC1 AND 2/BUS2/28VDC [44WV] .
B. If the test confirms the fault:
Subtask 24-60-00-710-063-A - Do a check of the status of the EIS/SDAC1 & 2/BUS2/28VDC circuit breaker (44WV).
- Remove SDAC1 AMM 31-55-34-000-001.
- Replace SDAC-1 [1WV1] AMM 31-55-34-400-001.
- Install SDAC1 AMM 31-55-34-400-001.
- Remove SDAC2 AMM 31-55-34-000-001.
- Replace SDAC-2 [1WV2] AMM 31-55-34-400-001.
- Do a check and repair the wiring between:
. 28VDC BUS 2 (202PP) and the first branch point, with the circuit breaker (44WV) included
. 28VDC BUS 2 (202PP) and pin 4 of module 14PN, the circuit breaker (1PN2) included, ASM 315408 and ASM 246101. - Install SDAC2 AMM 31-55-34-400-001.
- Do the trouble shooting procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace C/B-EIS/SDAC1 AND 2/BUS2/28VDC [44WV] .
C. Do this Test:
5. Close-up| ACTION | RESULT |
|---|---|
On the ECAM control panel:
| On the lower ECAM DU, on the ELEC page:
|
On the upper ECAM DU:
|
Subtask 24-60-00-860-061-A
A. Put the aircraft back to its initial configuration.
(1) Do the EIS stop procedure
AMM 31-60-00-860-002.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
(1) Do the EIS stop procedure
AMM 31-60-00-860-002.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.