W DOC AIRBUS | TSM A320F

Galley Supply Fault


TASK 24-56-00-810-801-A
Galley Supply Fault


1. Possible Causes
  • GND FAIL RELAY 4XA
  • GALLEY SPLY RELAY 5XA
  • GALLEY SPLY RELAY 9XA
  • MAN GALLEY SPLY RELAY 6XA
  • wiring
  • GALLEY PWR RELAY
  • MAIN GALLEY SPLY RELAY 6XA
  • PBSW 2XA
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-56-00-710-001
Operational Test of the Galley Supply
ASM 245601
3. Fault Confirmation
Subtask 24-56-00-710-050-A
A. Do a test of the galley supply AMM 24-56-00-710-001.
4. Fault Isolation
Subtask 24-56-00-810-050-A ** ON A/C NOT FOR ALL
A. If the white indicator light FAULT in PBSW 2XA comes on during the test:
  • do a check of the GND FAIL RELAY 4XA and replace it if necessary.
   (1) If the fault continues:
  • do a check of the GALLEY SPLY RELAY 5XA and replace it if necessary.
   (2) If the fault continues:
  • do a check of the GALLEY SPLY RELAY 9XA and replace it if necessary.
   (3) If the fault continues:
  • do a check of the MAN GALLEY SPLY RELAY 6XA and replace it if necessary.
   (4) If the fault continues:
  • do a check and repair the wiring if necessary between:
    PBSW 2XA connector A/C1 and GND FAIL RELAY 4XA connector A/A,
    GND FAIL RELAY 4XA connector A/A and GALLEY SPLY RELAY 5XA connector A/X,
    GND FAIL RELAY 4XA connector A/A and GALLEY SPLY RELAY 9XA connector A/X, (if fitted),
    GALLEY SPLY RELAY 5XA connector A/Z and GND,
    GALLEY SPLY RELAY 9XA connector A/Z and GND (if fitted),
    CB 7MC and related GALLEY PWR RELAY pin X,
    CB 7MC and related GALLEY PWR RELAY connector B/3,
    related GALLEY PWR RELAY pin Z and GND,
    related GALLEY PWR RELAY connector B/5 and GND ASM 245601.
   (5) If the fault continues:
  • do a check for 115 VAC at the pins B,C,D and E,F,G, and I,J,K at the related GALLEYS.
     (a) If there is no 115 VAC :
  • do a check of the related GALLEY PWR RELAY and replace it if necessary.
   (6) If the fault continues:
  • do a check and repair the wiring between the related:
    GALLEY pins B,C,D or E,F,G or I,J,K and the related CB,
    GALLEY pins A or H or L and the related GND ASM 245601.
Subtask 24-56-00-810-050-B ** ON A/C NOT FOR ALL
A. If the white indicator light FAULT in PBSW 2XA comes on during the test:
  • do a check of the GND FAIL RELAY 4XA and replace it if necessary.
   (1) If the fault continues:
  • do a check of the GALLEY SPLY RELAY 5XA and replace it if necessary.
   (2) If the fault continues:
  • do a check of the GALLEY SPLY RELAY 9XA and replace it if necessary.
   (3) If the fault continues:
  • do a check of the MAIN GALLEY SPLY RELAY 6XA and replace it if necessary.
   (4) If the fault continues:
  • do a check and repair the wiring if necessary between:
    PBSW 2XA connector A/C1 and GND FAIL RELAY 4XA connector A/A,
    GND FAIL RELAY 4XA connector A/A and GALLEY SPLY RELAY 5XA connector A/X,
    GND FAIL RELAY 4XA connector A/A and GALLEY SPLY RELAY 9XA connector A/X (if fitted),
    GALLEY SPLY RELAY 5XA connector A/A and MAIN GALLEY SPLY RELAY 6XA connector A/A (if fitted),
    GALLEY SPLY RELAY 9XA connector A/A and MAIN GALLEY SPLY RELAY 6XA connector A/A (if fitted),
    GALLEY SPLY RELAY 5XA connector A/Z and GND (if fitted),
    GALLEY SPLY RELAY 9XA connector A/Z and GND (if fitted),
    CB 7MC and related GALLEY PWR RELAY pin X,
    CB 7MC and related GALLEY PWR RELAY connector B/3,
    related GALLEY PWR RELAY pin Z and GND,
    related GALLEY PWR RELAY connector B/5 and GND ASM 245601.
   (5) If the fault continues:
  • do a check for 115 VAC at the pins B,C,D and E,F,G, and I,J,K at the related GALLEYS.
     (a) If there is no 115 VAC :
  • do a check of the related GALLEY PWR RELAY and replace it if necessary.
   (6) If the fault continues:
  • do a check and repair the wiring between the related:
    GALLEY pins B,C,D or E,F,G or I,J,K and the related CB,
    GALLEY pins A or H or L and the related GND ASM 245601.
Subtask 24-56-00-810-051-A
B. If the white indicator light FAULT in PBSW 2XA does not come on, but there is a fault in the galley equipment:
  • do a check of the PBSW 2XA and replace it if necessary.
   (1) If the fault continues:
  • do a check and repair the wiring between:
    CB 1XA and PBSW 2XA connector A/C3 ASM 245601.
Subtask 24-56-00-710-051-A
C. Do the test as given in Para. 3.A. to check the correct operation (no maintenance message is shown).
[Rev.8 from Aug 2018] 2026.04.04 04:39:05 UTC