Galley Supply Fault
TASK 24-56-00-810-801-A
Galley Supply Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-56-00-710-050-A 4. Fault Isolation
Subtask 24-56-00-810-050-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:57 UTC
Galley Supply Fault
1. Possible Causes
- GND FAIL RELAY 4XA
- GALLEY SPLY RELAY 5XA
- GALLEY SPLY RELAY 9XA
- MAN GALLEY SPLY RELAY 6XA
- wiring
- GALLEY PWR RELAY
- MAIN GALLEY SPLY RELAY 6XA
- PBSW 2XA
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-56-00-710-001 | Operational Test of the Galley Supply |
| ASM 245601 |
Subtask 24-56-00-710-050-A 4. Fault Isolation
Subtask 24-56-00-810-050-A ** ON A/C NOT FOR ALL
A. If the white indicator light FAULT in PBSW 2XA comes on during the test:
Subtask 24-56-00-810-050-B ** ON A/C NOT FOR ALL - do a check of the GND FAIL RELAY 4XA and replace it if necessary.
- do a check of the GALLEY SPLY RELAY 5XA and replace it if necessary.
- do a check of the GALLEY SPLY RELAY 9XA and replace it if necessary.
- do a check of the MAN GALLEY SPLY RELAY 6XA and replace it if necessary.
- do a check and repair the wiring if necessary between:
PBSW 2XA connector A/C1 and GND FAIL RELAY 4XA connector A/A,
GND FAIL RELAY 4XA connector A/A and GALLEY SPLY RELAY 5XA connector A/X,
GND FAIL RELAY 4XA connector A/A and GALLEY SPLY RELAY 9XA connector A/X, (if fitted),
GALLEY SPLY RELAY 5XA connector A/Z and GND,
GALLEY SPLY RELAY 9XA connector A/Z and GND (if fitted),
CB 7MC and related GALLEY PWR RELAY pin X,
CB 7MC and related GALLEY PWR RELAY connector B/3,
related GALLEY PWR RELAY pin Z and GND,
related GALLEY PWR RELAY connector B/5 and GND ASM 245601.
- do a check for 115 VAC at the pins B,C,D and E,F,G, and I,J,K at the related GALLEYS.
- do a check of the related GALLEY PWR RELAY and replace it if necessary.
- do a check and repair the wiring between the related:
GALLEY pins B,C,D or E,F,G or I,J,K and the related CB,
GALLEY pins A or H or L and the related GND ASM 245601.
A. If the white indicator light FAULT in PBSW 2XA comes on during the test:
Subtask 24-56-00-810-051-A - do a check of the GND FAIL RELAY 4XA and replace it if necessary.
- do a check of the GALLEY SPLY RELAY 5XA and replace it if necessary.
- do a check of the GALLEY SPLY RELAY 9XA and replace it if necessary.
- do a check of the MAIN GALLEY SPLY RELAY 6XA and replace it if necessary.
- do a check and repair the wiring if necessary between:
PBSW 2XA connector A/C1 and GND FAIL RELAY 4XA connector A/A,
GND FAIL RELAY 4XA connector A/A and GALLEY SPLY RELAY 5XA connector A/X,
GND FAIL RELAY 4XA connector A/A and GALLEY SPLY RELAY 9XA connector A/X (if fitted),
GALLEY SPLY RELAY 5XA connector A/A and MAIN GALLEY SPLY RELAY 6XA connector A/A (if fitted),
GALLEY SPLY RELAY 9XA connector A/A and MAIN GALLEY SPLY RELAY 6XA connector A/A (if fitted),
GALLEY SPLY RELAY 5XA connector A/Z and GND (if fitted),
GALLEY SPLY RELAY 9XA connector A/Z and GND (if fitted),
CB 7MC and related GALLEY PWR RELAY pin X,
CB 7MC and related GALLEY PWR RELAY connector B/3,
related GALLEY PWR RELAY pin Z and GND,
related GALLEY PWR RELAY connector B/5 and GND ASM 245601.
- do a check for 115 VAC at the pins B,C,D and E,F,G, and I,J,K at the related GALLEYS.
- do a check of the related GALLEY PWR RELAY and replace it if necessary.
- do a check and repair the wiring between the related:
GALLEY pins B,C,D or E,F,G or I,J,K and the related CB,
GALLEY pins A or H or L and the related GND ASM 245601.
B. If the white indicator light FAULT in PBSW 2XA does not come on, but there is a fault in the galley equipment:
Subtask 24-56-00-710-051-A - do a check of the PBSW 2XA and replace it if necessary.
- do a check and repair the wiring between:
CB 1XA and PBSW 2XA connector A/C3 ASM 245601.
C. Do the test as given in Para. 3.A. to check the correct operation (no maintenance message is shown).