Loss of the AC BUS 1
TASK 24-50-00-810-812-A
Loss of the AC BUS 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-50-00-860-070-A
Subtask 24-50-00-810-061-A ** ON A/C NOT FOR ALL
Subtask 24-50-00-860-071-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:56 UTC
Loss of the AC BUS 1
1. Possible Causes
- feeders
- IDG [4000XU]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-21-51-000-040 | Removal of the Integrated Drive Generator - IDG 1(2) |
| AMM 24-21-51-400-040 | Installation of the Integrated Drive Generator - IDG 1(2) |
| AWM 242201 | |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AWM 245105 | |
| AWM 245107 | |
| AWM 245109 | |
| AMM 31-60-00-860-001 | EIS Start Procedure |
Subtask 24-50-00-860-070-A
A. Job Set-up
(1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
Subtask 24-50-00-710-072-A (1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
B. Test
Do this test:
4. Fault IsolationDo this test:
| ACTION | RESULT |
|---|---|
1.On the ECAM control panel:
| On the upper ECAM display unit:
|
Subtask 24-50-00-810-061-A ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
Subtask 24-50-00-810-061-D ** ON A/C NOT FOR ALL - do a check of the feeders between the GLC1 (9XU1) and the busbar 1XP AWM 245105, AWM 245107 and AWM 245109.
- repair them.
- do a check of the feeders between the GLC1 (9XU1) and the IDG1 (4000XU) for a short to ground or a short circuit AWM 242201.
- repair them.
- replace the engine 1 IDG [4000XU] AMM 24-21-51-000-040 and AMM 24-21-51-400-040.
A. If the test confirms the fault:
Subtask 24-50-00-710-073-A - do a check of the feeders between the GLC1 (9XU1) and the busbar 1XP AWM 245105, AWM 245107 and AWM 245109.
- repair them.
- do a check of the feeders between the GLC1 (9XU1) and the IDG1 (4000XU) for a short to ground or a short circuit AWM 242201.
- repair them.
- replace the engine 1 IDG [4000XU] AMM 24-21-51-000-040 and AMM 24-21-51-400-040.
B. Do this test to make sure that the system operates correctly:
5. Close-up| ACTION | RESULT |
|---|---|
On the ECAM control panel:
| On the lower ECAM display unit:
|
Subtask 24-50-00-860-071-A
A. Put the aircraft back to its initial configuration.
(1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
(1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.