Failure of the AC BUS 2 with the APU Generator in Operation
TASK 24-50-00-810-811-A
Failure of the AC BUS 2 with the APU Generator in Operation
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-50-00-860-068-A
Subtask 24-50-00-865-055-A
Subtask 24-50-00-860-069-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:56 UTC
Failure of the AC BUS 2 with the APU Generator in Operation
1. Possible Causes
- BTC-2 [11XU2]
- wiring
- RELAY-GLC 2 AUX CTL [4XU2]
- GLC-2 [9XU2]
- RELAY-SMOKE [30XU2]
- RELAY-BUS TIE [30XU1]
- C/B-ELEC/GEN2/OFF/BTC2 SPLY [8XU]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-00-00-810-803-A | Circuit Breaker Tripped and/or C/B TRIPPED Warning |
| ASM 242203 | |
| AMM 24-22-34-000-001 | Removal of the GCU-1(2) |
| AMM 24-22-34-400-001 | Installation of the GCU-1(2) |
| AMM 24-22-55-000-001 | Removal of the Contactors |
| AMM 24-22-55-400-002 | Installation of the Contactors |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 31-60-00-860-001 | EIS Start Procedure |
Subtask 24-50-00-860-068-A
A. Job Set-up
(1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
Subtask 24-50-00-710-070-A (1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
B. Test
(1) Do this test:
4. Fault Isolation(1) Do this test:
| ACTION | RESULT |
|---|---|
1.On the ELEC panel 35VU:
| On the ELEC panel 35VU:
|
Subtask 24-50-00-865-055-A
A. Table of the circuit breakers used in this procedure:
Subtask 24-50-00-810-060-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | ELEC/GEN2/OFF/BTC2 SPLY | 8XU | T31 |
B. If the test confirms the fault:
Subtask 24-50-00-810-060-B ** ON A/C NOT FOR ALL - Do a check of the status of the circuit breaker (8XU).
- Replace BTC-2 [11XU2] AMM 24-22-55-000-001 and AMM 24-22-55-400-002.
- Do a check and repair the wiring between the pin B/5 of BTC2 and pin AA/9C of GCU2 ASM 242203.
- Do a check for 28VDC:
- Replace the RELAY-GLC 2 AUX CTL [4XU2] .
- Repair the wiring between the circuit breaker ELEC/GEN2/OFF/BTC2 SPLY (8XU) and the pin A/A3 of the relay (4XU2) ASM 242203.
- Replace GLC-2 [9XU2] AMM 24-22-55-000-001 and AMM 24-22-55-400-002.
- Repair the wiring between the pin A/A2 of the relay (4XU2) and pin B/8 of GLC2 (9XU2) ASM 242203.
- Replace the RELAY-SMOKE [30XU2] .
- Repair the wiring between the pin A/A2 of the relay (4XU2) and pin B/8 of GLC2 (9XU2) ASM 242203.
- Replace RELAY-BUS TIE [30XU1] .
- Do a check and repair the wiring between:
. Pin B/6 of GLC2 (9XU2) and pins A/B2 and A/X1 of the relay (30XU2) ASM 242203,
. Pin A/B3 of the relay (30XU2) and pin B/3 of BTC2 (11XU2) ASM 242203.
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace the C/B-ELEC/GEN2/OFF/BTC2 SPLY [8XU] .
B. If the test confirms the fault:
1 Remove the GLC2 auxiliary control-relay (4XU2) and do a check for 28VDC at pin A/A3 on the base of the GLC2 auxiliary control-relay (4XU2).
a If there is 28VDC:
a If there is no 28VDC:
a If there is no 28VDC:
a If there is no 28VDC:
Subtask 24-50-00-710-071-A - Do a check of the status of the ELEC/GEN2/OFF/BTC2 SPLY circuit breaker (8XU).
- Replace BTC-2 [11XU2] AMM 24-22-55-000-001 and AMM 24-22-55-400-002.
- Remove GCU2 AMM 24-22-34-000-001.
- Do a check and repair the wiring between pin B/5 of BTC2 (11XU2) and pin AA/9A of GCU2 (1XU2) ASM 242203.
- Install GCU2 AMM 24-22-34-400-001.
1 Remove the GLC2 auxiliary control-relay (4XU2) and do a check for 28VDC at pin A/A3 on the base of the GLC2 auxiliary control-relay (4XU2).
a If there is 28VDC:
- Replace the RELAY-GLC 2 AUX CTL [4XU2] .
- Repair the wiring between the ELEC/GEN2/OFF/BTC2 SPLY circuit breaker (8XU) and pin A/A3 of the GLC2 auxiliary control-relay (4XU2) ASM 242203.
a If there is no 28VDC:
- Replace GLC-2 [9XU2] AMM 24-22-55-000-001 and AMM 24-22-55-400-002.
- Repair the wiring between pin A/A2 of the relay (4XU2) and pin B/8 of GLC2 (9XU2) ASM 242203.
a If there is no 28VDC:
- Replace the RELAY-SMOKE [30XU2] .
- Repair the wiring between pin A/A2 of the GLC2 auxiliary control-relay (4XU2) and pin B/24 of GLC2 (9XU2) ASM 242203.
a If there is no 28VDC:
- Replace RELAY-SMOKE [30XU2] .
- Do a check and repair the wiring ASM 242203 between:
. Pin B/22 of GLC2 (9XU2) and pins A/B1 and A/X1 of the smoke relay (30XU2)
. Pin A/B3 of the smoke relay (30XU2) and pin B/3 of BTC2 (11XU2).
- Do the circuit breaker tripped and/or C/B TRIPPED warning procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace the C/B-ELEC/GEN2/OFF/BTC2 SPLY [8XU] .
C. Do this test to make sure that the system operates correctly:
5. Close-up| ACTION | RESULT |
|---|---|
On the ECAM control panel:
| On the lower ECAM display unit:
|
Subtask 24-50-00-860-069-A
A. Put the aircraft back to its initial configuration.
(1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
(1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.