Unwanted ELEC AC BUS 2 FAULT Warning
TASK 24-50-00-810-807-A
Unwanted ELEC AC BUS 2 FAULT Warning
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-50-00-860-060-A
Subtask 24-50-00-810-056-A
Subtask 24-50-00-860-061-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:56 UTC
Unwanted ELEC AC BUS 2 FAULT Warning
1. Possible Causes
- SDAC-1 [1WV1]
- SDAC-2 [1WV2]
- RELAY-BUS 2XP CTL [16XC]
- wiring
RELAY-BUS 2XP CTL (20XN2) - C/B-ELEC/BUS/2XP/CTL [17XN2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-00-00-810-803-A | Circuit Breaker Tripped and/or C/B TRIPPED Warning |
| ASM 242501 | |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| ASM 245103 | |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
| AMM 31-60-00-860-001 | EIS Start Procedure |
Subtask 24-50-00-860-060-A
A. Job Set-up
(1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
Subtask 24-50-00-710-062-A (1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
B. Test
(1) Do this test:
4. Fault Isolation(1) Do this test:
| ACTION | RESULT |
|---|---|
1.On the ECAM control panel:
| On the lower ECAM DU, on the ELEC page:
|
| | On the upper ECAM DU:
|
Subtask 24-50-00-810-056-A
A. If the test confirms the fault:
Subtask 24-50-00-710-063-A - Do a check of the status of the ELEC/BUS/2XP/CTL circuit breaker (17XN2).
- Remove SDAC1 AMM 31-55-34-000-001.
- Replace SDAC-1 [1WV1] AMM 31-55-34-400-001.
- Install SDAC1 AMM 31-55-34-400-001.
- Remove SDAC2 AMM 31-55-34-000-001.
- Replace SDAC-2 [1WV2] AMM 31-55-34-400-001.
- Replace RELAY-BUS 2XP CTL [16XC] .
- Install SDAC2 AMM 31-55-34-400-001.
- Do a check for continuity and repair the wiring between:
. Pin A/X1 of the BUS 2XP control relay (16XC) and the ELEC/BUS/2XP/CTL circuit breaker (17XN2)
. Pin A/X2 of the BUS 2XP control relay (16XC) and the ground, ASM 242501
. Pin A/X1 of the BUS 2XP control relay (20XN2) and the first branch point, ASM 245103. - Do a check for a short to ground and for a short circuit of the wiring between:
. Pins AD/5K of SDAC1 and SDAC2 and the pin A/B2 of the bus 2XP control relay (16XC),
ASM 242501.
- Do the trouble shooting procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace RELAY-BUS 2XP CTL [16XC] .
- Replace
RELAY-BUS 2XP CTL (20XN2) .
- Replace C/B-ELEC/BUS/2XP/CTL [17XN2] .
B. Do this test to make sure that the system operates correctly:
5. Close-up| ACTION | RESULT |
|---|---|
1.On the ECAM control panel:
| On the lower ECAM DU, on the ELEC page:
|
On the upper ECAM DU:
|
Subtask 24-50-00-860-061-A
A. Put the aircraft back to its initial configuration.
(1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
(1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.