Unwanted ELEC AC BUS 1 FAULT Warning


TASK 24-50-00-810-806-A
Unwanted ELEC AC BUS 1 FAULT Warning


1. Possible Causes
  • SDAC-1 [1WV1]
  • SDAC-2 [1WV2]
  • RELAY-BUS 1XP CTL [15XC]
  • wiring
  • RELAY-BUS 1XP CTL (20XN1)
  • C/B-ELEC/AC/BUS1/CTL [17XN1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 24-00-00-810-803-A
Circuit Breaker Tripped and/or C/B TRIPPED Warning
ASM 242501
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
ASM 245102
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
AMM 31-60-00-860-001
EIS Start Procedure
3. Fault Confirmation
Subtask 24-50-00-860-058-A
A. Job Set-up
   (1) Aircraft Maintenance Configuration
     (a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
     (b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
Subtask 24-50-00-710-060-A
B. Test
   (1) Do this test:
ACTION
RESULT
1.On the ECAM control panel:
  • Push the ELEC key to get the ELEC page.
On the lower ECAM DU, on the ELEC page:
  • The normal configuration comes into view with the AC 1 busbar indication shown in amber.
On the upper ECAM DU:
  • The ELEC AC BUS 1 FAULT warning comes into view.
4. Fault Isolation
Subtask 24-50-00-810-055-A
A. If the test confirms the fault:
  • Do a check of the status of the ELEC/AC/BUS1/CTL circuit breaker (17XN1).
   (1) If the circuit breaker is closed:
     (a) If the fault does not continue:
     (b) If the fault continues:
       1 If the fault does not continue:
       2 If the fault continues:
         a If the fault continues:
  • Do a check for continuity and repair the wiring between:
    . Pin A/X1 of the BUS 1XP control relay (15XC) and the ELEC/AC/BUS1/CTL circuit breaker (17XN1)
    . Pin A/X2 of the BUS 1XP control relay (15XC) and the ground, ASM 242501
    . Pin A/X1 of the BUS 1XP control relay (20XN1) and the first branch point, ASM 245102.
  • Do a check for a short to ground and for a short circuit of the wiring between:
    . Pins AA/5D of SDAC 1 and SDAC 2 and the pin A/B2 of the bus 1XP control relay (15XC), ASM 242501.
   (2) If the circuit breaker is open:
     (a) If the fault continues:
  • Replace RELAY-BUS 1XP CTL [15XC] .
       1 If the fault continues:
  • Replace RELAY-BUS 1XP CTL (20XN1).
       2 If the fault continues:
  • Replace C/B-ELEC/AC/BUS1/CTL [17XN1] .
Subtask 24-50-00-710-061-A
B. Do this test to make sure that the system operates correctly:
ACTION
RESULT
1.On the ECAM control panel:
  • Push the ELEC key to get the ELEC page.
On the lower ECAM DU, on the ELEC page:
  • The normal configuration comes into view.
On the upper ECAM DU:
  • No message comes into view.
5. Close-up
Subtask 24-50-00-860-059-A
A. Put the aircraft back to its initial configuration.
   (1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
   (2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.