W DOC AIRBUS | TSM A320F

Unwanted AC ESS BUS FAULT Warning


TASK 24-50-00-810-803-A
Unwanted AC ESS BUS FAULT Warning


1. Possible Causes
  • SDAC-1 [1WV1]
  • SDAC-2 [1WV2]
  • 3XH
  • wiring
  • C/B-AC ESS BUS/MONG/SPLY [2XH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 24-00-00-810-803-A
Circuit Breaker Tripped and/or C/B TRIPPED Warning
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
ASM 245201
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
AMM 31-60-00-860-001
EIS Start Procedure
3. Fault Confirmation
Subtask 24-50-00-860-054-A
A. Job Set-up
   (1) Aircraft Maintenance Configuration
     (a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
Subtask 24-50-00-710-054-A
B. Test
   (1) Do the EIS start procedure to make sure that the EIS operates correctly AMM 31-60-00-860-001.
   (2) Do this test:
ACTION
RESULT
1.On the ECAM control panel:
  • Push the ELEC key to get the ELEC page.
On the lower ECAM DU, on the ELEC page:
  • The normal configuration comes into view with the AC ESS indication shown in amber.
On the upper ECAM DU:
  • The ELEC AC ESS BUS FAULT warning comes into view.
4. Fault Isolation
Subtask 24-50-00-810-052-A
A. If the test gives the ELEC AC ESS BUS FAULT warning on the upper ECAM DU when the EIS operates correctly:
  • Do a check of the status of the AC ESS BUS/MONG/SPLY circuit breaker (2XH).
   (1) If the circuit breaker is closed:
     (a) If the fault does not continue:
     (b) If the fault continues:
       1 If the fault does not continue:
       2 If the fault continues:
         a If the fault continues:
  • Do a check for continuity and repair the wiring between:
    . The AC ESS BUS/MONG/SPLY circuit breaker (2XH) and pin A/X of the bus 4XP control relay (3XH)
    . Pin A/Z of the bus 4XP control relay (3XH) and the ground.
  • Do a check for a short to ground and for a short circuit of the wiring between:
    . Pin A/A of the bus 4XP control relay (3XH) and pins AD/5E of SDAC1 and 2, ASM 245201.
   (2) If the circuit breaker is open:
     (a) If the fault continues:
  • Replace relay 3XH .
       1 If the fault continues:
Replace C/B-AC ESS BUS/MONG/SPLY [2XH] .
Subtask 24-50-00-710-055-A
B. Do this test to make sure that the system operates correctly:
ACTION
RESULT
1.On the ECAM control panel:
  • Push the ELEC key to get the ELEC page.
On the lower ECAM DU, on the ELEC page:
  • The normal configuration comes into view.
On the upper ECAM DU:
  • No message comes into view.
5. Close-up
Subtask 24-50-00-860-055-A
A. Put the aircraft back to its initial configuration.
   (1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
   (2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
[Rev.8 from Aug 2018] 2026.04.04 04:26:55 UTC