W DOC AIRBUS | TSM A320F

The EXT PWR/NOT IN USE Indicator Light Stays off when the EXT PWR Energizes the Aircraft


TASK 24-40-00-810-809-A
The EXT PWR/NOT IN USE Indicator Light Stays off when the EXT PWR Energizes the Aircraft


1. Possible Causes
  • wiring
  • IND LT-EXT PWR/NOT IN USE [8XG]
  • CNTOR-AC GND SVCE SPLY [12XX]
  • EPC [3XG]
  • EGIU-1 [22XU1]
  • P/BSW-ELEC/EXT PWR [10XG]
  • lamp
  • GAPCU [24XG]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-22-33-000-001
Removal of the EGIU-1(2)
AMM 24-22-33-400-002
Installation of the EGIU-1(2)
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
ASM 244101
AMM 24-41-34-000-001
Removal of the Ground Power Control Unit (GPCU)
AMM 24-41-34-400-001
Installation of the Ground Power Control Unit (GPCU)
AMM 24-41-55-000-001
Removal of the External Power Contactor (EPC)
AMM 24-41-55-400-001
Installation of the External Power Contactor (EPC)
AMM 24-42-55-000-001
Removal of the Contactors
AMM 24-42-55-400-001
Installation of the Contactors
3. Fault Confirmation
Subtask 24-40-00-710-056-A
A. Test
   (1) Energize the aircraft electrical circuits from the external power AMM 24-41-00-861-002
NOTE: Energization of the aircraft is correct but, during the procedure given at Para. 3.D., make sure that:
  • on the external power panel 108VU: the EXT PWR/NOT IN USE indicator light stays off and the EXT PWR/AVAIL caution light comes on
  • on the ELEC panel 35VU: the AVAIL legend of the EXT PWR pushbutton switch comes on.
4. Fault Isolation
Subtask 24-40-00-810-058-A ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
  • on the external power panel 108VU, push the LIGHT TEST pushbutton switch (34LP) to do a test of the lights of the external power panel 108VU.
   (1) If the EXT PWR/NOT IN USE indicator light comes on:
  • do a check of the wiring between the pin 2 of the circuit breaker (6XG) and the pin 2 of the EXT PWR/NOT IN USE indicator light (8XG) ASM 244101.
     (a) If there is no continuity:
  • repair the wiring.
     (b) If there is continuity:
  • replace the IND LT-EXT PWR/NOT IN USE [8XG] .
       1 If the fault continues:
       2 If the fault continues:
       3 If the fault continues:
       4 If the fault continues:
  • replace the P/BSW-ELEC/EXT PWR [10XG] .
         a If the fault continues:
  • do a check and repair the wiring ASM 244101 between:
    . pin A/X2 of the EPC auxiliary control relay (5XG) and pin AB/3C of the EGIU 1 (22XU1)
    . pin 2 of the circuit breaker (11XG) and pin AB/5C of the EGIU 1 (22XU1)
    . pin AB/5C of the EGIU 1 (22XU1) and pin A/B1 of the ELEC/EXT PWR pushbutton switch (10XG)
    . pin AB/4C of the EGIU 1 (22XU1) and pin A/B3 of the ELEC/EXT PWR pushbutton switch (10XG).
   (2) If the EXT PWR/NOT IN USE indicator light (8XG) stays off:
  • replace the lamp of the EXT PWR/NOT IN USE indicator light (8XG).
     (a) If the fault continues:
  • do a check of the wiring ASM 244101 between:
    . pins 4 and 1 of the EXT PWR/NOT IN USE indicator light (8XG)
    . pin 5 of the EXT PWR/NOT IN USE indicator light (8XG) and the first terminal.
       1 If there is no continuity:
  • repair the wiring.
       2 If there is continuity:
  • replace the IND LT-EXT PWR/NOT IN USE [8XG] .
Subtask 24-40-00-810-058-B ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
  • on the external power panel 108VU, push the LIGHT TEST pushbutton switch (34LP) to do a test of the lights of the external power panel 108VU.
   (1) If the EXT PWR/NOT IN USE indicator light comes on:
  • do a check of the wiring between the pin 2 of the circuit breaker (6XG) and the pin 2 of the EXT PWR/NOT IN USE indicator light (8XG) ASM 244101.
     (a) If there is no continuity:
  • repair the wiring.
     (b) If there is continuity:
  • replace the IND LT-EXT PWR/NOT IN USE [8XG] .
       1 If the fault continues:
       2 If the fault continues:
       3 If the fault continues:
       4 If the fault continues:
  • replace the P/BSW-ELEC/EXT PWR [10XG] .
         a If the fault continues:
  • do a check and repair the wiring ASM 244101 between:
    . pin A/X2 of the EPC auxiliary control relay (5XG) and pin AB/10A of the GAPCU (24XG)
    . pin AA/4A of the GAPCU (24XG) and pin A/B1 of the ELEC/EXT PWR pushbutton switch (10XG)
    . pin A/B3 of the ELEC/EXT PWR pushbutton switch (10XG) and the ground.
   (2) If the EXT PWR/NOT IN USE indicator light (8XG) stays off:
  • replace the lamp of the EXT PWR/NOT IN USE indicator light (8XG).
     (a) If the fault continues:
  • do a check of the wiring ASM 244101 between:
    . pins 4 and 1 of the EXT PWR/NOT IN USE indicator light (8XG)
    . pin 5 of the EXT PWR/NOT IN USE indicator light (8XG) and the first terminal.
       1 If there is no continuity:
  • repair the wiring.
       2 If there is continuity:
  • replace the IND LT-EXT PWR/NOT IN USE [8XG] .
Subtask 24-40-00-710-057-A
B. Do this test to make sure that the system operates correctly.
   (1) Do the test given in Para. 3. and make sure that:
  • on the external power panel 108VU the EXT PWR/NOT IN USE indicator light and EXT PWR/AVAIL caution light come on.
  • on the ELEC panel 35VU, the AVAIL legend of the EXT PWR pushbutton switch comes on.
   (2) De-energize the aircraft electrical circuits from the external power AMM 24-41-00-862-002.
[Rev.8 from Aug 2018] 2026.04.04 04:40:16 UTC