W DOC AIRBUS | TSM A320F

The EXT PWR/AVAIL Caution Light Stays off when the EXT PWR Energizes the Aircraft


TASK 24-40-00-810-808-A
The EXT PWR/AVAIL Caution Light Stays off when the EXT PWR Energizes the Aircraft


1. Possible Causes
  • wiring
  • CAUT LT-EXT PWR/AVAIL [9XG]
  • lamp
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
ASM 244101
3. Fault Confirmation
Subtask 24-40-00-710-054-A ** ON A/C NOT FOR ALL
A. Test
   (1) Energize the aircraft electrical circuits from the external power AMM 24-41-00-861-002
NOTE: Energization of the aircraft is correct but, during the procedure given at Para. 3.D., make sure that:
  • on the panel 108VU: the EXT PWR/NOT IN USE indicator light comes on and the EXT PWR/AVAIL caution light stays off.
  • on the panel 35VU: the AVAIL legend of the EXT PWR pushbutton switch comes on.
4. Fault Isolation
Subtask 24-40-00-810-057-A ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
  • on the panel 108VU, push the LIGHT TEST pushbutton switch (34LP) to do a test of the lights of the panel 108VU.
   (1) If the EXT PWR/AVAIL caution light comes on:
  • do a check of the wiring between the pin 2 of the circuit breaker (4XG) and the first terminal block ASM 244101.
     (a) If there is no continuity:
  • repair the above wiring.
     (b) If there is continuity:
  • replace the CAUT LT-EXT PWR/AVAIL [9XG] .
   (2) If the EXT PWR/AVAIL caution light stays off:
  • replace the lamp of the EXT PWR/AVAIL caution light.
     (a) If the fault continues:
  • do a check of the wiring :
    . between the pin 23 of the diode module (1191VD) and the first terminal block
    . between the pin 2 of the caution light and the pin 8 of the diode module (1191VD)
    . between the pins 1 and 4 of the caution light
    . between the pin 5 of the caution light and the first terminal block ASM 244101..
       1 If there is no continuity:
  • repair the above wiring.
       2 If there is continuity:
  • replace the CAUT LT-EXT PWR/AVAIL [9XG] .
Subtask 24-40-00-710-055-A ** ON A/C NOT FOR ALL
B. Do this test to make sure that the system operates correctly.
   (1) Do the test given in Para. 3. and make sure that:
  • on the panel 108VU, the EXT PWR/NOT IN USE indicator light and EXT PWR/AVAIL caution light come on.
  • on the panel 35VU, the AVAIL legend of the EXT PWR pushbutton switch comes on.
   (2) De-energize the aircraft electrical circuits from the external power AMM 24-41-00-862-002.