W DOC AIRBUS | TSM A320F

Failure of the External Power Receptacle


TASK 24-40-00-810-803-A
Failure of the External Power Receptacle


1. Possible Causes
  • GPCU [1XG]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 24-00-00-810-803-A
Circuit Breaker Tripped and/or C/B TRIPPED Warning
AMM 24-41-00-740-004
Operational Check of the GPCU via the CFDS
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
ASM 244101
AMM 24-41-34-000-001
Removal of the Ground Power Control Unit (GPCU)
AMM 24-41-34-400-001
Installation of the Ground Power Control Unit (GPCU)
3. Fault Confirmation
Subtask 24-40-00-860-054-A ** ON A/C NOT FOR ALL
A. Job Set-Up
   (1) Aircraft Maintenance Configuration
     (a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002
Subtask 24-40-00-740-052-A ** ON A/C NOT FOR ALL
B. Test
Do the operational check of the GPCU with the CFDS AMM 24-41-00-740-004.
4. Fault Isolation
Subtask 24-40-00-810-052-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CHECK GPCU PINS C3, C4 RECEPTACLE 20XG PINS F, E and on the overhead panel, on the panel 35VU, the AVAIL legend of the EXT PWR pushbutton switch is on:
  • Do a check of the status of the 3A circuit breaker on the front face of the GPCU:
   (1) If the circuit breaker is open:
     (a) If the fault continues:
   (2) If the circuit breaker is closed:
  • Do a check of the wiring for open circuit between the pin AC/4 of the GPCU and the pin F of the external power receptacle ASM 244101.
     (a) If the wiring is not correct:
  • Repair the wiring .
     (b) If the wiring is correct:
  • Replace the external power unit.
     (c) If the fault continues:
Subtask 24-40-00-700-055-A ** ON A/C NOT FOR ALL
B. Make sure that the aircraft electrical circuits operate correctly in ground configuration.
   (1) Energize the aircraft electrical circuits from the external power AMM 24-41-00-861-002.
   (2) De- energize the aircraft electrical circuits from the external power AMM 24-41-00-862-002.
5. Close-up
Subtask 24-40-00-860-055-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
   (2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002
[Rev.8 from Aug 2018] 2026.04.04 04:26:52 UTC