Failure of the External Power Receptacle
TASK 24-40-00-810-803-A
Failure of the External Power Receptacle
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-40-00-860-054-A ** ON A/C NOT FOR ALL
Subtask 24-40-00-810-052-A ** ON A/C NOT FOR ALL
Subtask 24-40-00-860-055-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:52 UTC
Failure of the External Power Receptacle
1. Possible Causes
- GPCU [1XG]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-00-00-810-803-A | Circuit Breaker Tripped and/or C/B TRIPPED Warning |
| AMM 24-41-00-740-004 | Operational Check of the GPCU via the CFDS |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| ASM 244101 | |
| AMM 24-41-34-000-001 | Removal of the Ground Power Control Unit (GPCU) |
| AMM 24-41-34-400-001 | Installation of the Ground Power Control Unit (GPCU) |
Subtask 24-40-00-860-054-A ** ON A/C NOT FOR ALL
A. Job Set-Up
(1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002
Subtask 24-40-00-740-052-A ** ON A/C NOT FOR ALL 4. Fault Isolation(1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002
Subtask 24-40-00-810-052-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CHECK GPCU PINS C3, C4 RECEPTACLE 20XG PINS F, E and on the overhead panel, on the panel 35VU, the AVAIL legend of the EXT PWR pushbutton switch is on:
Subtask 24-40-00-700-055-A ** ON A/C NOT FOR ALL - Do a check of the status of the 3A circuit breaker on the front face of the GPCU:
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace the GPCU [1XG] AMM 24-41-34-000-001 and AMM 24-41-34-400-001.
- Do a check of the wiring for open circuit between the pin AC/4 of the GPCU and the pin F of the external power receptacle ASM 244101.
- Repair the wiring .
- Replace the external power unit.
- Replace the GPCU [1XG] AMM 24-41-34-000-001 and AMM 24-41-34-400-001.
B. Make sure that the aircraft electrical circuits operate correctly in ground configuration.
(1) Energize the aircraft electrical circuits from the external power AMM 24-41-00-861-002.
(2) De- energize the aircraft electrical circuits from the external power AMM 24-41-00-862-002.
5. Close-up(1) Energize the aircraft electrical circuits from the external power AMM 24-41-00-861-002.
(2) De- energize the aircraft electrical circuits from the external power AMM 24-41-00-862-002.
Subtask 24-40-00-860-055-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002
(1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002