W DOC AIRBUS | TSM A320F

Failure of the Indication of the Battery Voltmeter 1 or 2


TASK 24-38-00-810-849-A
Failure of the Indication of the Battery Voltmeter 1 or 2


1. Possible Causes
  • SW-INT LT/ANN LT [33LP]
  • wiring
  • VOLTMETER-BAT 1 [3PV1]
  • VOLTMETER-BAT 2 [3PV2]
  • CLOCK [2FS]
  • RMI-VOR/DME [11FN]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-37-21-000-001
Removal of the Voltmeters
AMM 24-37-21-400-001
Installation of the Voltmeters
AMM 31-21-21-000-001
Removal of the Clock
AMM 31-21-21-400-001
Installation of the Clock
ASM 331402
AMM 34-57-22-000-001
Removal of the VOR/DME RMI
AMM 34-57-22-400-001
Installation of the VOR/DME RMI
3. Fault Confirmation
Subtask 24-38-00-710-134-A
A. Test
   (1) On the ELEC panel 35VU, the battery voltmeter 1 or the battery voltmeter 2 shows the indication 888.
4. Fault Isolation
Subtask 24-38-00-810-104-A ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
  • make sure that the INT LT/ANN LT switch (33LP) is in the BRT or DIM position
  • do a check of the status of the auxiliary contact of the INT LT/ANN LT switch (33LP) between pin 3D and pin 1D (normally open) ASM 331402.
   (1) If the contact is closed:
  • replace the SW-INT LT/ANN LT [33LP] .
   (2) If the contact is open:
  • do a check of the wiring ASM 331402 for a short to ground between:
    . pin 3D of the INT LT/ANN LT switch (33LP) and pin H of the battery voltmeter 1 (3PV1)
    . pin 3D of the INT LT/ANN LT switch and pin H of the battery voltmeter 2 (3PV2)
    . pin 3D of the INT LT/ANN LT switch and pin A/J of the clock (2FS)
    . pin 3D of the INT LT/ANN LT switch and pin A/d of the VOR/DME RMI (11FN).
     (a) If the wiring is not correct:
  • repair or replace it.
     (b) If the wiring is correct:
       1 If the fault continues:
         a If the fault continues:
Subtask 24-38-00-810-104-D ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
  • Make sure that the INT LT/ANN LT switch (33LP) is in the BRT or DIM position.
  • Do a check of the status of the auxiliary contact of the INT LT/ANN LT switch (33LP) between pin 3D and pin 1D (normally open) ASM 331402.
   (1) If the contact is closed:
  • Replace SW-INT LT/ANN LT [33LP] .
   (2) If the contact is open:
  • Do a check of the wiring ASM 331402 for a short to ground between:
    . Pin 3D of the INT LT/ANN LT switch (33LP) and pin H of the battery voltmeter 1 (3PV1)
    . Pin 3D of the INT LT/ANN LT switch and pin H of the battery voltmeter 2 (3PV2)
    . Pin 3D of the INT LT/ANN LT switch and pin A/J of the clock (2FS).
     (a) If the wiring is not correct:
  • Repair it.
     (b) If the wiring is correct:
       1 If the fault continues:
         a If the fault continues:
Subtask 24-38-00-710-135-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:26:51 UTC