No Electrical Parameters of the BAT2 are shown on the ELEC Page
TASK 24-38-00-810-842-A
No Electrical Parameters of the BAT2 are shown on the ELEC Page
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-38-00-710-122-A
Subtask 24-38-00-810-093-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:51 UTC
No Electrical Parameters of the BAT2 are shown on the ELEC Page
1. Possible Causes
- BCL-2 [1PB2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-38-00-710-001 | Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) |
| AMM 24-38-34-000-001 | Removal of the Battery Charge Limiter (BCL) |
| AMM 24-38-34-400-001 | Installation of the Battery Charge Limiter (BCL) |
Subtask 24-38-00-710-122-A
A. TEST
Do the operational test of the Battery Charge Limiter (BCL) (with the CFDS) AMM 24-38-00-710-001.
4. Fault IsolationDo the operational test of the Battery Charge Limiter (BCL) (with the CFDS) AMM 24-38-00-710-001.
Subtask 24-38-00-810-093-A
A. If the test of the BCL is correct and if the battery voltage on the applicable voltmeter has the specified value (28VDC):
Subtask 24-38-00-710-123-A - replace the BCL-2 [1PB2] , AMM 24-38-34-000-001 and AMM 24-38-34-400-001.
B. Do the operational test of the Battery Charge Limiter (BCL) (without the CFDS) to make sure that the system operates correctly AMM 24-38-00-710-001.