No Electrical Parameters of the BAT1 are shown on the ELEC Page


TASK 24-38-00-810-841-A
No Electrical Parameters of the BAT1 are shown on the ELEC Page


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-38-00-710-001
Operational Test of the Battery Charge Limiter (BCL), (with the CFDS)
AMM 24-38-34-000-001
Removal of the Battery Charge Limiter (BCL)
AMM 24-38-34-400-001
Installation of the Battery Charge Limiter (BCL)
3. Fault Confirmation
Subtask 24-38-00-710-120-A
A. Test
Do the operational test of the Battery charge Limiter (BCL) (with the CFDS) AMM 24-38-00-710-001.
4. Fault Isolation
Subtask 24-38-00-810-092-A
A. If the test of the BCL is correct and if the battery voltage on the applicable voltmeter has the specified value (28VDC):
Subtask 24-38-00-710-121-A
B. Do the operational test of the Battery Charge Limiter (BCL) (without the CFDS) to make sure that the system operates correctly AMM 24-38-00-710-001.