W DOC AIRBUS | TSM A320F

Loss of the EMERGENCY CONFIGURATION Signal to the BCL1


TASK 24-38-00-810-830-A
Loss of the EMERGENCY CONFIGURATION Signal to the BCL1


1. Possible Causes
  • BCL-1 [1PB1]
  • wiring
  • RELAY-BUS 1XP CTL [15XC]
  • RELAY-BUS 2XP CTL [16XC]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-38-00-710-001
Operational Test of the Battery Charge Limiter (BCL), (with the CFDS)
ASM 243801
AMM 24-38-34-000-001
Removal of the Battery Charge Limiter (BCL)
AMM 24-38-34-400-001
Installation of the Battery Charge Limiter (BCL)
3. Fault Confirmation
Subtask 24-38-00-710-100-A
A. Test
   (1) Do the operational test of the BCL1 AMM 24-38-00-710-001.
4. Fault Isolation
Subtask 24-38-00-810-079-A
A. If the test gives the maintenance message RELAYS 15XC or 16XC/BCL1 CIRCUIT
   (1) If the fault continues:
  • do a check of the wiring from the pin A/Y of the BCL1 to the pin A/A3 of the relay (15XC) and from the pin A/A2 of this relay to the pin A/A3 of the relay (16XC) ASM 243801.
     (a) If there is no continuity:
  • repair the wiring.
     (b) If there is continuity:
  • do a check of the wiring from the pin A/A2 of the relay (16XC) to the first terminal block ASM 243801.
       1 If there is no continuity:
  • repair the wiring.
       2 If there is continuity:
  • replace the RELAY-BUS 1XP CTL [15XC]
         a If the fault continues:
  • replace the RELAY-BUS 2XP CTL [16XC] .
Subtask 24-38-00-710-101-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:26:49 UTC