Loss of the NOSE L/G LOCKED-UP Signal to the BCL2
TASK 24-38-00-810-829-A
Loss of the NOSE L/G LOCKED-UP Signal to the BCL2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-38-00-710-098-A 4. Fault Isolation
Subtask 24-38-00-810-078-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:49 UTC
Loss of the NOSE L/G LOCKED-UP Signal to the BCL2
1. Possible Causes
- BCL-2 [1PB2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-38-00-710-001 | Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) |
| ASM 243802 | |
| AMM 24-38-34-000-001 | Removal of the Battery Charge Limiter (BCL) |
| AMM 24-38-34-400-001 | Installation of the Battery Charge Limiter (BCL) |
Subtask 24-38-00-710-098-A 4. Fault Isolation
Subtask 24-38-00-810-078-A
A. If the test gives the maintenance message CHECK LGCIU1/BCL2 CIRCUIT
Subtask 24-38-00-710-099-A - replace the BCL-2 [1PB2] AMM 24-38-34-000-001 and AMM 24-38-34-400-001.
- do a check and repair the wiring from the pin A/s of the BCL2 to the first terminal block ASM 243802.
B. Do the test given in Para. 3.