Failure of the BAT2 FAULT Indication Circuit
TASK 24-38-00-810-827-A
Failure of the BAT2 FAULT Indication Circuit
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-38-00-710-094-A 4. Fault Isolation
Subtask 24-38-00-810-076-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:48 UTC
Failure of the BAT2 FAULT Indication Circuit
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-38-00-710-001 | Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) |
| ASM 243802 | |
| AMM 24-38-34-000-001 | Removal of the Battery Charge Limiter (BCL) |
| AMM 24-38-34-400-001 | Installation of the Battery Charge Limiter (BCL) |
| AMM 33-14-33-000-001 | Removal of the Annunciator-Light Test and Interface-Board |
| AMM 33-14-33-400-001 | Installation of the Annunciator-Light Test and Interface-Board |
Subtask 24-38-00-710-094-A 4. Fault Isolation
Subtask 24-38-00-810-076-A
A. If the test gives the maintenance message BOARD 5LP/BCL2 CIRCUIT:
Subtask 24-38-00-710-095-A - replace the BCL-2 [1PB2] AMM 24-38-34-000-001 and AMM 24-38-34-400-001.
- replace the BOARD-ANN LT TEST & INTFC [5LP] AMM 33-14-33-000-001 and AMM 33-14-33-400-001.
- do a check of the wiring from the circuit breaker (9PB1) to the pin A/H of the BCL2 (1PB2) ASM 243802.
- repair the wiring.
- replace the P/BSW-ELEC/BAT 2 [7PB2] .
B. Do the test given in Para. 3.