Failure of the Supply from the 28VDC HOT BUS (701PP)
TASK 24-38-00-810-824-A
Failure of the Supply from the 28VDC HOT BUS (701PP)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-38-00-710-088-A 4. Fault Isolation
Subtask 24-38-00-810-073-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:48 UTC
Failure of the Supply from the 28VDC HOT BUS (701PP)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-38-00-710-001 | Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) |
| ASM 243801 | |
| AMM 24-38-34-000-001 | Removal of the Battery Charge Limiter (BCL) |
| AMM 24-38-34-400-001 | Installation of the Battery Charge Limiter (BCL) |
Subtask 24-38-00-710-088-A 4. Fault Isolation
Subtask 24-38-00-810-073-A
A. If the test gives the maintenance message CHECK HOT BUS 701PP/BCL1 CIRCUIT:
Subtask 24-38-00-710-089-A - do a check of the wiring for open circuit between the BAT REF/BCL1 circuit breaker (9PB1) and the pin A/C of the BCL1 ASM 243801.
- repair it.
- replace the P/BSW-ELEC/BAT 1 [7PB1] .
- replace the BCL-1 [1PB1] AMM 24-38-34-000-001 and AMM 24-38-34-400-001.
B. Do the test given in Para. 3.