W DOC AIRBUS | TSM A320F

Failure of the Supply from the 28VDC HOT BUS (701PP)


TASK 24-38-00-810-824-A
Failure of the Supply from the 28VDC HOT BUS (701PP)


1. Possible Causes
  • wiring
  • P/BSW-ELEC/BAT 1 [7PB1]
  • BCL-1 [1PB1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-38-00-710-001
Operational Test of the Battery Charge Limiter (BCL), (with the CFDS)
ASM 243801
AMM 24-38-34-000-001
Removal of the Battery Charge Limiter (BCL)
AMM 24-38-34-400-001
Installation of the Battery Charge Limiter (BCL)
3. Fault Confirmation
Subtask 24-38-00-710-088-A
A. Test
Do the operational test of the BCL AMM 24-38-00-710-001.
4. Fault Isolation
Subtask 24-38-00-810-073-A
A. If the test gives the maintenance message CHECK HOT BUS 701PP/BCL1 CIRCUIT:
  • do a check of the wiring for open circuit between the BAT REF/BCL1 circuit breaker (9PB1) and the pin A/C of the BCL1 ASM 243801.
   (1) If the wiring is not correct:
  • repair it.
   (2) If the wiring is correct:
  • replace the P/BSW-ELEC/BAT 1 [7PB1] .
   (3) If the fault continues:
Subtask 24-38-00-710-089-A
B. Do the test given in Para. 3.