Failure of the Electrical Wiring between the BCL2 and the ADIRU1 or the LGCIU
TASK 24-38-00-810-823-A
Failure of the Electrical Wiring between the BCL2 and the ADIRU1 or the LGCIU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-38-00-710-086-A 4. Fault Isolation
Subtask 24-38-00-810-072-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:48 UTC
Failure of the Electrical Wiring between the BCL2 and the ADIRU1 or the LGCIU
1. Possible Causes
- wiring
- BCL-2 [1PB2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242402 | |
| AMM 24-38-00-710-001 | Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) |
| ASM 243801 | |
| AMM 24-38-34-000-001 | Removal of the Battery Charge Limiter (BCL) |
| AMM 24-38-34-400-001 | Installation of the Battery Charge Limiter (BCL) |
Subtask 24-38-00-710-086-A 4. Fault Isolation
Subtask 24-38-00-810-072-A
A. If the test gives the maintenance message BCL2 : LGCIU/ADIRU1 SIGNAL DISAGREE:
Subtask 24-38-00-710-087-A NOTE: This CFDS message can be found with these CFDS messages:
. LGCIU1 or
. ADIRU1 and
BCL1 : LGCIU/ADIRU1 SIGNAL DISAGREE.
In this case, do the related trouble shooting.
If not, do the trouble shooting given below:
(1) If the wiring is not correct: . LGCIU1 or
. ADIRU1 and
BCL1 : LGCIU/ADIRU1 SIGNAL DISAGREE.
In this case, do the related trouble shooting.
If not, do the trouble shooting given below:
- do a check of the wiring for open circuit or short to ground:
. from the pin A/g of the BCL2 to the first branch point.
. between the pin A/K of the BCL2 and the pin B/4C of the LGCIU1 ASM 242402 and ASM 243801.
- repair it.
- replace the BCL-2 [1PB2] AMM 24-38-34-000-001 and AMM 24-38-34-400-001.
B. Do the test given in Para. 3.A.