Failure of the Electrical Wiring between the BCL2 and the ADIRU1 or the LGCIU


TASK 24-38-00-810-823-A
Failure of the Electrical Wiring between the BCL2 and the ADIRU1 or the LGCIU


1. Possible Causes
  • wiring
  • BCL-2 [1PB2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 242402
AMM 24-38-00-710-001
Operational Test of the Battery Charge Limiter (BCL), (with the CFDS)
ASM 243801
AMM 24-38-34-000-001
Removal of the Battery Charge Limiter (BCL)
AMM 24-38-34-400-001
Installation of the Battery Charge Limiter (BCL)
3. Fault Confirmation
Subtask 24-38-00-710-086-A
A. Test
Do the operational test of the BCL2 AMM 24-38-00-710-001.
4. Fault Isolation
Subtask 24-38-00-810-072-A
A. If the test gives the maintenance message BCL2 : LGCIU/ADIRU1 SIGNAL DISAGREE:
NOTE: This CFDS message can be found with these CFDS messages:
. LGCIU1 or
. ADIRU1 and
BCL1 : LGCIU/ADIRU1 SIGNAL DISAGREE.
In this case, do the related trouble shooting.
If not, do the trouble shooting given below:
  • do a check of the wiring for open circuit or short to ground:
    . from the pin A/g of the BCL2 to the first branch point.
    . between the pin A/K of the BCL2 and the pin B/4C of the LGCIU1 ASM 242402 and ASM 243801.
   (1) If the wiring is not correct:
  • repair it.
   (2) If the wiring is correct:
Subtask 24-38-00-710-087-A
B. Do the test given in Para. 3.A.