Failure of the Electrical Wiring between the BCL1 and the ADIRU1 or the LGCIU
TASK 24-38-00-810-822-A
Failure of the Electrical Wiring between the BCL1 and the ADIRU1 or the LGCIU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-38-00-710-084-A 4. Fault Isolation
Subtask 24-38-00-810-071-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:48 UTC
Failure of the Electrical Wiring between the BCL1 and the ADIRU1 or the LGCIU
1. Possible Causes
- wiring
- BCL-1 [1PB1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242402 | |
| AMM 24-38-00-710-001 | Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) |
| ASM 243801 | |
| AMM 24-38-34-000-001 | Removal of the Battery Charge Limiter (BCL) |
| AMM 24-38-34-400-001 | Installation of the Battery Charge Limiter (BCL) |
Subtask 24-38-00-710-084-A 4. Fault Isolation
Subtask 24-38-00-810-071-A
A. If the test gives the maintenance message BCL1 : LGCIU/ADIRU1 SIGNAL DISAGREE:
Subtask 24-38-00-710-085-A NOTE: This CFDS message can be found with these CFDS messages:
. LGCIU1 or
. ADIRU1 and
BCL2 : LGCIU/ADIRU1 SIGNAL DISAGREE.
In this case, refer to the related trouble shooting.
If not do the trouble shooting given below:
(1) If the wiring is not correct: . LGCIU1 or
. ADIRU1 and
BCL2 : LGCIU/ADIRU1 SIGNAL DISAGREE.
In this case, refer to the related trouble shooting.
If not do the trouble shooting given below:
- do a check of the wiring for open circuit or short to ground:
. from the pin A/g of the BCL1 to the first branch point
. between the pin A/K of the BCL1 and the pin B/2D of the LGCIU1 ASM 242402 and ASM 243801.
- repair it.
- replace the BCL-1 [1PB1] AMM 24-38-34-000-001 and AMM 24-38-34-400-001.
B. Do the test given in Para. 3.