Internal Passive Failure of the BCL1
TASK 24-38-00-810-820-A
Internal Passive Failure of the BCL1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-38-00-710-082-A 4. Fault Isolation
Subtask 24-38-00-810-069-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:48 UTC
Internal Passive Failure of the BCL1
1. Possible Causes
- BCL-1 [1PB1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-38-00-710-001 | Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) |
| AMM 24-38-34-000-001 | Removal of the Battery Charge Limiter (BCL) |
| AMM 24-38-34-400-001 | Installation of the Battery Charge Limiter (BCL) |
Subtask 24-38-00-710-082-A 4. Fault Isolation
Subtask 24-38-00-810-069-A
A. If the test gives the maintenance message BCL1:
- replace the BCL-1 [1PB1] AMM 24-38-34-000-001 and AMM 24-38-34-400-001.