Failure of the ADIRU Signal to the BCL1 and the BCL2
TASK 24-38-00-810-819-A
Failure of the ADIRU Signal to the BCL1 and the BCL2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-38-00-700-052-A
Subtask 24-38-00-810-068-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:48 UTC
Failure of the ADIRU Signal to the BCL1 and the BCL2
1. Possible Causes
- ADIRU-1 [1FP1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-38-00-710-001 | Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-13-00-740-002 | INTERFACE TEST of the ADR |
Subtask 24-38-00-700-052-A
A. Test
Do the operational test of the BCL1 and BCL2 AMM 24-38-00-710-001.
(1) If the test gives the maintenance messages BCL1 : LGCIU/ADIRU1 SIGNAL DISAGREE and BCL2 : LGCIU/ADIRU1 SIGNAL DISAGREE:
4. Fault IsolationDo the operational test of the BCL1 and BCL2 AMM 24-38-00-710-001.
(1) If the test gives the maintenance messages BCL1 : LGCIU/ADIRU1 SIGNAL DISAGREE and BCL2 : LGCIU/ADIRU1 SIGNAL DISAGREE:
- do the Interface test of the ADR system (system 1) AMM 34-13-00-740-002.
- do the trouble shooting given in Para. 4.A.
- do the related trouble shooting.
Subtask 24-38-00-810-068-A
A. If the test confirms the failure:
- replace the ADIRU-1 [1FP1] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.