Failure of the LGCIU Signal to the BCL1
TASK 24-38-00-810-817-A
Failure of the LGCIU Signal to the BCL1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-38-00-700-050-A
Subtask 24-38-00-810-066-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:48 UTC
Failure of the LGCIU Signal to the BCL1
1. Possible Causes
- LGCIU-1 [5GA1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-38-00-710-001 | Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) |
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
| AMM 32-69-00-740-001 | BITE Check of Landing-Gear Control Interface-Unit (LGCIU) With Use of MCDU to Ensure that Continuous BITE is Operative |
Subtask 24-38-00-700-050-A
A. Test
Do the operational test of the BCL1 AMM 24-38-00-710-001.
(1) If the test gives the message BCL1 : LGCIU/ADIRU1 SIGNAL DISAGREE:
- do the trouble shooting given in the fault isolation.
(b) If the test gives another maintenance message:
4. Fault IsolationDo the operational test of the BCL1 AMM 24-38-00-710-001.
(1) If the test gives the message BCL1 : LGCIU/ADIRU1 SIGNAL DISAGREE:
- do the BITE test of the landing gear AMM 32-69-00-740-001.
- do the trouble shooting given in the fault isolation.
(b) If the test gives another maintenance message:
- do the related trouble shooting.
Subtask 24-38-00-810-066-A
A. Procedure
(1) If the test confirms the fault:
(1) If the test confirms the fault:
- swap the LGCIU1 and the LGCIU2 AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
- swap back the LGCIU1 and the LGCIU2 and replace the LGCIU-1 [5GA1] AMM 32-31-71-000-001 and AMM 32-31-71-400-001.