W DOC AIRBUS | TSM A320F

Failure of the LGCIU Signal to the BCL1


TASK 24-38-00-810-817-A
Failure of the LGCIU Signal to the BCL1


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-38-00-710-001
Operational Test of the Battery Charge Limiter (BCL), (with the CFDS)
AMM 32-31-71-000-001
Removal of the LGCIU
AMM 32-31-71-400-001
Installation of the LGCIU
AMM 32-69-00-740-001
BITE Check of Landing-Gear Control Interface-Unit (LGCIU) With Use of MCDU to Ensure that Continuous BITE is Operative
3. Fault Confirmation
Subtask 24-38-00-700-050-A
A. Test
Do the operational test of the BCL1 AMM 24-38-00-710-001.
   (1) If the test gives the message BCL1 : LGCIU/ADIRU1 SIGNAL DISAGREE:
     (a) If the test gives the maintenance message LGCIU1:
- do the trouble shooting given in the fault isolation.
     (b) If the test gives another maintenance message:
  • do the related trouble shooting.
4. Fault Isolation
Subtask 24-38-00-810-066-A
A. Procedure
   (1) If the test confirms the fault:
   (2) If the fault moves to the other LGCIU position: