Failure of the Battery 2 Contactor
TASK 24-38-00-810-813-A
Failure of the Battery 2 Contactor
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-38-00-710-074-A 4. Fault Isolation
Subtask 24-38-00-810-062-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:47 UTC
Failure of the Battery 2 Contactor
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-38-00-710-001 | Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) |
| ASM 243802 | |
| AMM 24-38-34-000-001 | Removal of the Battery Charge Limiter (BCL) |
| AMM 24-38-34-400-001 | Installation of the Battery Charge Limiter (BCL) |
| AMM 24-38-55-000-001 | Removal of the Battery Line Contactor |
| AMM 24-38-55-400-001 | Installation of the Battery Line Contactor |
Subtask 24-38-00-710-074-A 4. Fault Isolation
Subtask 24-38-00-810-062-A
A. If the test gives the maintenance message CHECK CONTACTOR 6PB2/BCL 2 CIRCUIT:
Subtask 24-38-00-710-075-A - Replace the CNTOR-LINE, BAT 2 [6PB2] , AMM 24-38-55-000-001 and AMM 24-38-55-400-001.
- Replace the BCL-2 [1PB2] , AMM 24-38-34-000-001 and AMM 24-38-34-400-001.
- Do a check of the wiring ASM 243802 between:
. Pin B/5 of the battery 2 line contactor (6PB2) and pin A/G of the BCL 2 (1PB2).
. Pin B/3 of the battery 2 line contactor and pin 1 of the circuit breaker ELEC/HOT BUS/702PPSPLY (5PB2).
. Pin B/15 of the battery 2 line contactor and pin A/i of the BCL 2.
. Pin B/17 of battery 2 line contactor and the ground.
- Repair the wiring .
- Do a check and repair the wiring ASM 243802 between:
. Pin A/A1 of the battery 2 pushbutton switch (7PB2) and pin A/F of the BCL 2.
. Pin A/A3 of the battery 2 pushbutton switch and the ground.
B. Do the test given in Para. 3.