Failure of Electrical Wiring between the Essential TR Contactor and the BCL 2


TASK 24-38-00-810-812-A
Failure of Electrical Wiring between the Essential TR Contactor and the BCL 2


1. Possible Causes
  • CNTOR-ESS TR [3PE]
  • BCL-2 [1PB2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-34-55-000-001
Removal of the Essential TR Contactor
AMM 24-34-55-400-001
Installation of the Essential TR Contactor
AMM 24-38-00-710-001
Operational Test of the Battery Charge Limiter (BCL), (with the CFDS)
ASM 243801
AMM 24-38-34-000-001
Removal of the Battery Charge Limiter (BCL)
AMM 24-38-34-400-001
Installation of the Battery Charge Limiter (BCL)
3. Fault Confirmation
Subtask 24-38-00-710-072-A
A. Test
Do the operational test of the BCL 2 AMM 24-38-00-710-001.
4. Fault Isolation
Subtask 24-38-00-810-061-A
A. If the test gives the maintenance message CHECK CONTACTOR 3PE/BCL 2 CIRCUIT:
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring from the BCL 2 pin A/Z to the essential TR contactor pin B/15, and from the contactor pin B/17 to the ground, ASM 243801.
Subtask 24-38-00-710-073-A
B. Do the test given in Para. 3.