W DOC AIRBUS | TSM A320F

Failure of Current Acquisition Circuit of the BCL 2


TASK 24-38-00-810-811-A
Failure of Current Acquisition Circuit of the BCL 2


1. Possible Causes
  • SHUNT-BAT 2 [3PB2]
  • BCL-2 [1PB2]
  • wiring from the battery 2 shunt to the pins A/L, A/M and A/N of the BCL 2
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-38-00-710-001
Operational Test of the Battery Charge Limiter (BCL), (with the CFDS)
ASM 243801
AMM 24-38-34-000-001
Removal of the Battery Charge Limiter (BCL)
AMM 24-38-34-400-001
Installation of the Battery Charge Limiter (BCL)
3. Fault Confirmation
Subtask 24-38-00-710-070-A
A. Test
Do the operational test of the BCL 2 AMM 24-38-00-710-001.
4. Fault Isolation
Subtask 24-38-00-810-060-A
A. If the test gives the maintenance message SHUNT 3PB2/BCL2 CIRCUIT:
  • replace the SHUNT-BAT 2 [3PB2] .
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring from the battery 2 shunt to the pins A/L, A/M and A/N of the BCL 2 ASM 243801.
Subtask 24-38-00-710-071-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:26:47 UTC