Failure of the Battery 1 Contactor
TASK 24-38-00-810-806-A
Failure of the Battery 1 Contactor
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-38-00-710-060-A 4. Fault Isolation
Subtask 24-38-00-810-055-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:47 UTC
Failure of the Battery 1 Contactor
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-38-00-710-001 | Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) |
| ASM 243801 | |
| AMM 24-38-34-000-001 | Removal of the Battery Charge Limiter (BCL) |
| AMM 24-38-34-400-001 | Installation of the Battery Charge Limiter (BCL) |
| AMM 24-38-55-000-001 | Removal of the Battery Line Contactor |
| AMM 24-38-55-400-001 | Installation of the Battery Line Contactor |
Subtask 24-38-00-710-060-A 4. Fault Isolation
Subtask 24-38-00-810-055-A
A. If the test gives the maintenance message CHECK CONTACTOR 6PB1/BCL1 CIRCUIT:
Subtask 24-38-00-710-061-A - Replace the CNTOR-LINE, BAT 1 [6PB1] AMM 24-38-55-000-001 and AMM 24-38-55-400-001.
- Replace BCL-1 [1PB1] AMM 24-38-34-000-001 and AMM 24-38-34-400-001.
- Do a check of the wiring ASM 243801 between:
. Pin B/5 of the battery 1 line-contactor (6PB1) and pin A/G of BCL 1 (1PB1)
. Pin B/3 of the battery 1 line-contactor and pin 1 of circuit breaker FLT CTL/SEC 1/STBY/SPLY (22CE)
. Pin B/15 of the battery 1 line-contactor and pin A/<I of BCL 1 (1PB1)
. Pin B/17 of battery 1 line-contactor and the ground.
- Repair the wiring .
- Do a check and repair the wiring ASM 243801 between:
. Pin A/A1 of the battery 1 pushbutton-switch (7PB1) and pin A/F of BCL 1 (1PB1)
. Pin A/A3 of the battery 1 pushbutton-switch and the ground.
B. Do the test given in Para. 3.