Failure of the Electrical Wiring between the Essential TR Contactor and the BCL 1
TASK 24-38-00-810-805-A
Failure of the Electrical Wiring between the Essential TR Contactor and the BCL 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-38-00-710-058-A 4. Fault Isolation
Subtask 24-38-00-810-054-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:47 UTC
Failure of the Electrical Wiring between the Essential TR Contactor and the BCL 1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-34-55-000-001 | Removal of the Essential TR Contactor |
| AMM 24-34-55-400-001 | Installation of the Essential TR Contactor |
| AMM 24-38-00-710-001 | Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) |
| ASM 243801 | |
| AMM 24-38-34-000-001 | Removal of the Battery Charge Limiter (BCL) |
| AMM 24-38-34-400-001 | Installation of the Battery Charge Limiter (BCL) |
Subtask 24-38-00-710-058-A 4. Fault Isolation
Subtask 24-38-00-810-054-A
A. If the test gives the maintenance message CHECK CONTACTOR 3PE/BCL1 CIRCUIT:
Subtask 24-38-00-710-059-A - replace the CNTOR-ESS TR [3PE] , AMM 24-34-55-000-001 and AMM 24-34-55-400-001
- replace the BCL-1 [1PB1] , AMM 24-38-34-000-001 and AMM 24-38-34-400-001.
- do a check and repair the wiring from BCL 1 pin A/Z to essential TR contactor pin B/15, and from essential TR contactor pin B/17 to the ground ASM 243801.
B. Do the test given in Para. 3.