W DOC AIRBUS | TSM A320F

Unwanted DC EMER CONFIG Warning


TASK 24-35-00-810-807-A
Unwanted DC EMER CONFIG Warning


1. Possible Causes
  • SDAC-1 [1WV1]
  • SDAC-2 [1WV2]
  • wiring
  • C/B-SDAC/1 AND 2/28VDC/ESS BUS [12WV]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 24-00-00-810-803-A
Circuit Breaker Tripped and/or C/B TRIPPED Warning
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
ASM 315408
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
AMM 31-60-00-860-001
EIS Start Procedure
3. Fault Confirmation
Subtask 24-35-00-860-056-A
A. Job Set-up
   (1) Aircraft Maintenance Configuration
     (a) Energize the aircraft electrical circuits AMM 24-41-00-861-002.
     (b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) AMM 31-60-00-860-001.
Subtask 24-35-00-710-067-A
B. Test
   (1) Do this test:
ACTION
RESULT
1.On the ECAM control panel:
  • Push the ELEC key to get the ELEC page.
On the lower ECAM DU, on the ELEC page:
  • The normal configuration comes into view with the DC essential busbar indication shown in amber.
On the upper ECAM DU:
  • The ELEC DC EMER CONFIG warning comes into view.
4. Fault Isolation
Subtask 24-35-00-810-070-A
A. If the test confirms the fault:
  • Do a check of the status of the SDAC 1&2/28VDC/ESS BUS circuit breaker(12WV).
   (1) If the circuit breaker is closed:
     (a) If the fault does not continue:
     (b) If the fault continues:
       1 If the fault does not continue:
       2 If the fault continues:
         a If the fault continues:
- Do a check and repair the wiring between:
. The SDAC1&2/28VDC/ESS BUS circuit breaker (12WV) and the first branch point ASM 315408.
   (2) If the circuit breaker is open:
     (a) If the fault continues:
  • Replace C/B-SDAC/1 AND 2/28VDC/ESS BUS [12WV] .
Subtask 24-35-00-710-068-A
B. Do this test to make sure that the system operates correctly:
ACTION
RESULT
1.On the ECAM control panel:
  • Push the ELEC key to get the ELEC page.
On the lower ECAM DU, on the ELEC page:
  • The normal configuration comes into view.
On the upper ECAM DU:
  • No message comes into view.
5. Close-up
Subtask 24-35-00-860-057-A
A. Put the aircraft back to its initial configuration.
   (1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
   (2) De-energize the aircraft electrical circuits AMM 24-41-00-862-002.
[Rev.8 from Aug 2018] 2026.04.04 04:26:46 UTC