Failure of the Connection between the Essential TR Current Output and the SDAC1 and SDAC2
TASK 24-34-00-810-802-A
Failure of the Connection between the Essential TR Current Output and the SDAC1 and SDAC2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-34-00-860-052-A
Subtask 24-34-00-810-051-A
Subtask 24-34-00-860-053-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:46 UTC
Failure of the Connection between the Essential TR Current Output and the SDAC1 and SDAC2
1. Possible Causes
- wiring
- TR-ESS [1PE]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 243401 | |
| AMM 24-34-51-000-001 | Removal of the Essential Transformer Rectifier |
| AMM 24-34-51-400-001 | Installation of the Essential Transformer Rectifier |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 31-60-00-860-002 | EIS Stop Procedure |
Subtask 24-34-00-860-052-A
A. Job Set-Up
(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
Subtask 24-34-00-710-052-A (1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
B. Test
4. Fault Isolation| ACTION | RESULT |
|---|---|
On the ECAM control panel:
| On the lower ECAM DU, ELEC page:
|
Subtask 24-34-00-810-051-A
A. If the test confirms the fault:
Subtask 24-34-00-710-053-A - do a check of the wiring from the essential transformer rectifier pins B/B and B/C to the first terminal block ASM 243401.
- repair the wiring.
- replace the TR-ESS [1PE] > AMM 24-34-51-000-001 and AMM 24-34-51-400-001.
B. Do this test to make sure that the system operates correctly.
5. Close-up| ACTION | RESULT |
|---|---|
1.On the ECAM control panel:
| On the lower ECAM DU:
|
| | In the ESS TR box:
|
Subtask 24-34-00-860-053-A
A. Put the aircraft back to its initial configuration.
(1) Do the EIS stop procedure
AMM 31-60-00-860-002.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
(1) Do the EIS stop procedure
AMM 31-60-00-860-002.
(2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.