Failure of the Connection between the TR2 Current Output and the SDAC1 and SDAC2


TASK 24-32-00-810-804-A
Failure of the Connection between the TR2 Current Output and the SDAC1 and SDAC2


1. Possible Causes
  • wiring
  • TR-2 [1PU2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 243201
AMM 24-32-51-000-001
Removal of the Transformer Rectifier
AMM 24-32-51-400-001
Installation of the Transformer Rectifier
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
AMM 31-60-00-860-001
EIS Start Procedure
AMM 31-60-00-860-002
EIS Stop Procedure
3. Fault Confirmation
Subtask 24-32-00-860-056-A
A. Job Set-up
   (1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
   (2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
Subtask 24-32-00-710-056-A
B. Test
ACTION
RESULT
1.On the ECAM control panel:
  • push the ELEC key to get the ELEC page.
On the lower ECAM DU, ELEC page:
  • amber crosses are shown instead of the value of the TR2 current.
4. Fault Isolation
Subtask 24-32-00-810-053-A
A. If the test confirms the fault:
  • do a check of the wiring from the TR2 pins B/B and B/C to the first terminal block ASM 243201.
   (1) If there is no continuity:
  • repair the wiring.
   (2) If there is continuity:
Subtask 24-32-00-710-057-A
B. Do this test to make sure that the system operates correctly:
ACTION
RESULT
1.On the ECAM control panel:
  • push the ELEC key to get the ELEC page.
On the lower ECAM DU:
  • the ELEC page comes into view.

In the TR2 box:
  • the value of the TR2 current is shown in green.
5. Close-up
Subtask 24-32-00-860-057-A
A. Put the aircraft back to its initial configuration.
   (1) Do the EIS stop procedure
AMM 31-60-00-860-002.
   (2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.