Failure of one TR found by the CFDIU
TASK 24-30-00-810-809-A
Failure of one TR found by the CFDIU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-30-00-740-050-A 4. Fault Isolation
Subtask 24-30-00-810-058-B
[Rev.8 from Aug 2018]
2026.04.04 04:26:45 UTC
Failure of one TR found by the CFDIU
1. Possible Causes
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 243502 | |
| AMM 31-32-00-740-002 | BITE Test of the Centralized Fault Display Interface Unit (CFDIU) |
| ASM 313206 |
Subtask 24-30-00-740-050-A 4. Fault Isolation
Subtask 24-30-00-810-058-B
A. If the test gives the message TR:
Subtask 24-30-00-740-051-A - do a check for other CFDS messages or warnings related to the DC main generator system (TR) on the upper ECAM display unit.
- do the trouble shooting related to these messages or warnings.
- do a check and repair the wiring between:
. the pin A/A1 of the relay (8PC1) and the pin AA/1J of the CFDIU (1TW).
. the pin A/A1 of the relay (8PC2) and the pin AB/5A of the CFDIU ASM 243502 and ASM 313206.
B. Do the test given in Para.3.