W DOC AIRBUS | TSM A320F

Loss of the BCL1 Detected by the SDAC2


TASK 24-30-00-810-807-A
Loss of the BCL1 Detected by the SDAC2


1. Possible Causes
  • BAT-1 [2PB1]
  • FUSE-BAT 1 (4PB11)
  • BCL-1 [1PB1]
  • SDAC-2 [1WV2]
  • wiring
  • MODULE-DC BUS 1 CNTOR [13PN]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-38-00-960-801
Replacement of the DC Fuse 4PB11(4PB21)
AMM 24-38-34-000-001
Removal of the Battery Charge Limiter (BCL)
AMM 24-38-34-400-001
Installation of the Battery Charge Limiter (BCL)
AMM 24-38-51-000-001
Removal of the Batteries
AMM 24-38-51-400-001
Installation of the Batteries
AMM 24-61-58-000-001
Removal of the DC Bus 1 Contactor Module
AMM 24-61-58-400-001
Installation of the DC Bus 1 Contactor Module
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315403
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 24-30-00-710-062-A
A. Test
Do the operational test of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 24-30-00-810-056-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message SDAC2 : NO DATA FROM BCL1:
  • Do a check of the battery 1 voltage.
   (1) If the voltage is not correct:
   (2) If the voltage is correct:
     (a) If the fault continues:
     (b) If the fault continues:
       1 If the fault continues:
         a Do a check and repair the wiring between ASM 315403:
  • Pins AB/11G and AB/11H of SDAC2 (1WV2) and pins A/a and A/e of BCL1 (1PB1).
Subtask 24-30-00-810-056-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message SDAC2 : NO DATA FROM BCL1:
  • Do a check of the battery 1 voltage.
   (1) If the voltage is not correct:
   (2) If the voltage is correct:
     (a) If the fault continues:
       1 If the fault continues:
         a If the fault continues:
* Do a check of the wiring between ASM 315403:
  • Pins AB/11G and AB/11H of SDAC2 (1WV2) and pins A/d and A/e of BCL1 (1PB1).
    ** If the wiring is not correct:
    ** - Repair the wiring .
    ** If the wiring is correct:
    ** - Replace MODULE-DC BUS 1 CNTOR [13PN] AMM 24-61-58-000-001 and AMM 24-61-58-400-001.
Subtask 24-30-00-710-063-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:26:45 UTC