Internal Failure of the Static Inverter
TASK 24-30-00-810-803-A
Internal Failure of the Static Inverter
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-30-00-710-054-A 4. Fault Isolation
Subtask 24-30-00-810-052-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:44 UTC
Internal Failure of the Static Inverter
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242801 | |
| AMM 24-28-51-000-001 | Removal of the Static Inverter |
| AMM 24-28-51-400-001 | Installation of the Static Inverter |
| AMM 24-38-00-710-001 | Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) |
| AMM 24-38-34-000-001 | Removal of the Battery Charge Limiter (BCL) |
| AMM 24-38-34-400-001 | Installation of the Battery Charge Limiter (BCL) |
Subtask 24-30-00-710-054-A 4. Fault Isolation
Subtask 24-30-00-810-052-A
A. If the test gives the maintenance message STATIC INVERTER 3XB:
Subtask 24-30-00-710-055-A - replace the STAT INV [3XB] AMM 24-28-51-000-001 and AMM 24-28-51-400-001 .
- replace the BCL-1 [1PB1] AMM 24-38-34-000-001 and AMM 24-38-34-400-001 .
- do a check and repair the wiring between the BCL 1 (1PB1) pin A/<P and the static inverter (3XB) pin A/G ASM 242801.
B. Do the test given in Para. 3.