W DOC AIRBUS | TSM A320F

Internal Failure of the Static Inverter


TASK 24-30-00-810-803-A
Internal Failure of the Static Inverter


1. Possible Causes
  • STAT INV [3XB]
  • BCL-1 [1PB1]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 242801
AMM 24-28-51-000-001
Removal of the Static Inverter
AMM 24-28-51-400-001
Installation of the Static Inverter
AMM 24-38-00-710-001
Operational Test of the Battery Charge Limiter (BCL), (with the CFDS)
AMM 24-38-34-000-001
Removal of the Battery Charge Limiter (BCL)
AMM 24-38-34-400-001
Installation of the Battery Charge Limiter (BCL)
3. Fault Confirmation
Subtask 24-30-00-710-054-A
A. Test
Do the operational test of the BCL1 AMM 24-38-00-710-001.
4. Fault Isolation
Subtask 24-30-00-810-052-A
A. If the test gives the maintenance message STATIC INVERTER 3XB:
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring between the BCL 1 (1PB1) pin A/<P and the static inverter (3XB) pin A/G ASM 242801.
Subtask 24-30-00-710-055-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:26:44 UTC