Unwanted RAT #amp# EMER GEN Annunciator FAULT On
TASK 24-24-00-810-811-A
Unwanted RAT & EMER GEN Annunciator FAULT On
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-24-00-869-051-A
Subtask 24-24-00-810-067-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:43 UTC
Unwanted RAT & EMER GEN Annunciator FAULT On
1. Possible Causes
- BCL-1 [1PB1]
- BCL-2 [1PB2]
- wiring
RELAY-ANN 14XE SUPPLY (31XE) ANN-EMER ELEC PWR/RAT/&/EMER GEN (14XE)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242402 | |
| AMM 24-38-34-000-001 | Removal of the Battery Charge Limiter (BCL) |
| AMM 24-38-34-400-001 | Installation of the Battery Charge Limiter (BCL) |
Subtask 24-24-00-869-051-A
A. Test
Not applicable.
4. Fault IsolationNot applicable.
Subtask 24-24-00-810-067-A
A. If the FAULT legend of the RAT & EMER GEN annunciator (14XE) on the EMER ELEC PWR section of the overhead panel 21VU is on:
- Do a check for a ground signal on pin A/t of the BCL-1 (1PB1).
- Replace the BCL-1 [1PB1] AMM 24-38-34-000-001 and AMM 24-38-34-400-001.
- Replace the BCL-2 [1PB2] AMM 24-38-34-000-001 and AMM 24-38-34-400-001.
- Do a check of the wiring ASM 242402 between:
. Pin A/t of the BCL-1 (1PB1) and pin A/Z of the annunciator 14XE supply relay (31XE)
. Pin A/t of the BCL-2 (1PB2) and pin A/Z of the annunciator 14XE supply relay (31XE)
. Pin A/X of the annunciator 14XE supply relay (31XE) and pin 2 of the of the EMER/SHED/CNTOR/SPLY circuit breaker (1PH).
- Repair the wiring .
- Replace the
RELAY-ANN 14XE SUPPLY (31XE) .
- Do a check of the wiring ASM 242402 between:
. Pin 2 of the EMER/SHED/CNTOR/SPLY circuit breaker (1PH) and pin A/7 of the EMER ELEC PWR/RAT/&/EMER GEN annunciator (14XE)
. Pin A/8 of the EMER ELEC PWR/RAT/&/EMER GEN annunciator (14XE) and pin A/A of the annunciator 14XE supply relay (31XE)
. Pin A/2 and the ground.
- Repair the wiring .
- Replace
ANN-EMER ELEC PWR/RAT/&/EMER GEN (14XE) .