Failure of the CSM/G Control Unit Detected by the CFDIU
TASK 24-24-00-810-809-A
Failure of the CSM/G Control Unit Detected by the CFDIU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-24-00-740-050-A 4. Fault Isolation
Subtask 24-24-00-810-061-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:43 UTC
Failure of the CSM/G Control Unit Detected by the CFDIU
1. Possible Causes
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242401 | |
| AMM 31-32-00-740-002 | BITE Test of the Centralized Fault Display Interface Unit (CFDIU) |
| ASM 313206 |
Subtask 24-24-00-740-050-A 4. Fault Isolation
Subtask 24-24-00-810-061-A
A. If the test gives the message GCU EMER:
Subtask 24-24-00-740-051-A - do a check for other CFDS messages or upper ECAM DU warnings related to the AC emergency generation (CSM/G, GCU).
- do the trouble shooting related to these messages or warnings.
- do a check and repair the wiring between:
. pin A/W of the CSM/G control unit (1XE) and pin AA/4K of the CFDIU (1TW)
. pin A/V of the CSM/G control unit (1XE) and pin AB/4A of the CFDIU (1TW) ASM 242401 and ASM 313206.
B. Do the test given in Para. 3.