W DOC AIRBUS | TSM A320F

Unwanted Warning from the EMER GLC


TASK 24-24-00-810-808-A
Unwanted Warning from the EMER GLC


1. Possible Causes
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-24-00-710-001
Operational Test of the Emergency Generation System
AWM 242406
AWM 315425
3. Fault Confirmation
Subtask 24-24-00-710-064-A
A. Test
Do the operational test of the emergency generation system AMM 24-24-00-710-001.
4. Fault Isolation
Subtask 24-24-00-810-060-A
A. If the test confirms the fault:
  • do a check and repair the wiring between successively:
    . the pin A/X of the CSM/G control unit (1XE) and the pin E of the terminal block 1159VT5 AWM 242406
    . the pin N of the terminal block 1159VT5 and the pin D of the terminal block 1853VT71 AWM 315425.
Subtask 24-24-00-710-065-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:26:43 UTC