Unwanted Warning from the EMER GLC
TASK 24-24-00-810-808-A
Unwanted Warning from the EMER GLC
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-24-00-710-064-A 4. Fault Isolation
Subtask 24-24-00-810-060-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:43 UTC
Unwanted Warning from the EMER GLC
1. Possible Causes
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-24-00-710-001 | Operational Test of the Emergency Generation System |
| AWM 242406 | |
| AWM 315425 |
Subtask 24-24-00-710-064-A 4. Fault Isolation
Subtask 24-24-00-810-060-A
A. If the test confirms the fault:
Subtask 24-24-00-710-065-A - do a check and repair the wiring between successively:
. the pin A/X of the CSM/G control unit (1XE) and the pin E of the terminal block 1159VT5 AWM 242406
. the pin N of the terminal block 1159VT5 and the pin D of the terminal block 1853VT71 AWM 315425.
B. Do the test given in Para. 3.