Result of the EMER GEN Test Incorrect (Loss of the ESS TR)


TASK 24-24-00-810-807-A
Result of the EMER GEN Test Incorrect (Loss of the ESS TR)


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-24-00-710-001
Operational Test of the Emergency Generation System
AMM 24-34-51-000-001
Removal of the Essential Transformer Rectifier
AMM 24-34-51-400-001
Installation of the Essential Transformer Rectifier
3. Fault Confirmation
Subtask 24-24-00-710-062-A
A. Test
Do the operational test of the emergency generator system AMM 24-24-00-710-001.
   (1) If during the test:
on the upper ECAM display unit:
  • the ELEC ESS TR FAULT warning comes into view.
on the lower ECAM display unit:
  • the line between DC 1 bus and DC ESS bus comes on
  • the line between ESS TR and DC ESS bus goes off
do the trouble shooting given in Para. 4.
4. Fault Isolation
Subtask 24-24-00-810-059-A
A. If the test confirms the fault:
  • do a check of the status of the ESS TR voltage.
   (1) If the ESS TR voltage is 28VDC:
On the MCDU, on the SYSTEM REPORT/TEST page of the ELEC system :
  • reset the ESS TR
    or (if the CFDS is not available) in the relay box 103VU :
  • push the TR RESET pushbutton switch (15PU).
NOTE: To reset the ESS TR correctly, you must energize it.
When you de-energize TR1 or TR2, the ESS TR becomes energized.
     (a) If the fault continues:
   (2) If the ESS TR voltage is 0VDC:
Subtask 24-24-00-710-063-A
B. Do the test given in Para. 3.