EMER GEN Voltage and Frequency Indications Lost or Incorrect
TASK 24-24-00-810-804-A
EMER GEN Voltage and Frequency Indications Lost or Incorrect
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-24-00-710-056-A Subtask 24-24-00-710-066-A
Subtask 24-24-00-865-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:42 UTC
EMER GEN Voltage and Frequency Indications Lost or Incorrect
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-00-00-810-803-A | Circuit Breaker Tripped and/or C/B TRIPPED Warning |
| AMM 24-24-00-710-001 | Operational Test of the Emergency Generation System |
| ASM 242401 | |
| AMM 24-24-34-000-001 | Removal of the CSM/G Control Unit |
| AMM 24-24-34-400-001 | Installation of the CSM/G Control Unit |
| AMM 24-24-51-000-001 | Removal of the Constant Speed Motor/Generator (CSM/G) |
| AMM 24-24-51-400-001 | Installation of the Constant Speed Motor/Generator (CSM/G) |
| ASM 243501 |
Subtask 24-24-00-710-056-A Subtask 24-24-00-710-066-A
B. Test
4. Fault Isolation| ACTION | RESULT |
|---|---|
1.On the ECAM control panel:
| If on the lower ECAM DU, the voltage indication or the frequency indication shows in amber:
|
| | If on the lower ECAM DU, amber crosses replace the voltage and the frequency indications:
|
Subtask 24-24-00-865-050-A
A. Table of the circuit breakers used in this procedure:
Subtask 24-24-00-810-065-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 106VU | EMER/GEN/REF | 27WV | B05 |
| 106VU | AC ESS/BUS/EMER/CNTOR/SPLY | 15PC | C08 |
B. If the test confirms the fault:
Subtask 24-24-00-810-053-B - replace the CONTROL UNIT-CSM/G [1XE] AMM 24-24-34-000-001 and AMM 24-24-34-400-001.
- replace the CSM/G [8XE] AMM 24-24-51-000-001 and AMM 24-24-51-400-001.
- do a check and repair the wiring ASM 242401 between:
. the pin 2/D of the CSM/G (8XE) and the pin A/D of the CSM/G control unit (1XE)
. the pin 2/E of the CSM/G (8XE) and the pin A/E of the CSM/G control unit (1XE)
. the pin 2/F of the CSM/G (8XE) and the pin A/G of the CSM/G control unit (1XE)
. the pin 2/G of the CSM/G (8XE) and the pin A/H of the CSM/G control unit (1XE)
. the pin 2/H of the CSM/G (8XE) and the pin A/J of the CSM/G control unit (1XE)
- do a check and repair the wiring ASM 242401 between:
. the pin A/S of the CSM/G control unit (1XE) and the pin T1 of the GLC EMER (2XE)
. the pin A/R of the CSM/G control unit (1XE) and the pin T2 of the GLC EMER (2XE)
. the pin A/P of the CSM/G control unit (1XE) and the pin T3 of the GLC EMER (2XE).
C. If the test confirms the fault:
Subtask 24-24-00-710-057-A - Do a check of the position of the circuit breaker (27WV).
- Do a check for 115VAC at the pin 2 of the circuit breaker (27WV).
- Do a check and repair the wiring between ASM 243501:
. the pin 2 of the circuit breaker (27WV) and the first branch point
. the branch point and the pin AE/8B of the SDAC1 (1WV1) and the pin AE/8B of the SDAC2 (1WV2).
- Do a check and repair the wiring between the pin 1 of the circuit breaker (27WV) and the pin 1 of the circuit breaker (15PC) ASM 243501.
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace the C/B-EMER/GEN/REF [27WV] .
D. Do the test given in Para. 3.