Failure of the RAT/EMER GEN/FAULT Indication Circuit (Linked to the BCL2)
TASK 24-24-00-810-802-A
Failure of the RAT/EMER GEN/FAULT Indication Circuit (Linked to the BCL2)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-24-00-710-052-A 4. Fault Isolation
Subtask 24-24-00-810-051-A
[Rev.8 from Aug 2018]
2026.04.04 04:26:42 UTC
Failure of the RAT/EMER GEN/FAULT Indication Circuit (Linked to the BCL2)
1. Possible Causes
- wiring
- BCL-2 [1PB2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242402 | |
| AMM 24-38-00-710-001 | Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) |
| AMM 24-38-34-000-001 | Removal of the Battery Charge Limiter (BCL) |
| AMM 24-38-34-400-001 | Installation of the Battery Charge Limiter (BCL) |
Subtask 24-24-00-710-052-A 4. Fault Isolation
Subtask 24-24-00-810-051-A
A. If the test gives the maintenance message RELAY 31XE/BCL2 CIRCUIT:
Subtask 24-24-00-710-053-A NOTE: This CFDS message can be found with the subsequent CFDS message: RELAY 31XE/BCL1 CIRCUIT. In this case, refer to the related trouble shooting.
If not, do the trouble shooting given below.
(1) If the fault continues: If not, do the trouble shooting given below.
- do a check of the wiring from the pin A/t of the BCL2 to the first branch point ASM 242402.
- replace the BCL-2 [1PB2] AMM 24-38-34-000-001 and AMM 24-38-34-400-001.
B. Do the test given in Para. 3.