Failure of the Neutral-To-Phase System of the APU Generator or the GAPCU
TASK 24-23-00-810-822-A
Failure of the Neutral-To-Phase System of the APU Generator or the GAPCU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-23-00-869-061-A ** ON A/C NOT FOR ALL
Subtask 24-23-00-810-075-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:41 UTC
Failure of the Neutral-To-Phase System of the APU Generator or the GAPCU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242301 | |
| AMM 24-23-51-000-001 | Removal of the APU Generator |
| AMM 24-23-51-400-001 | Installation of the APU Generator |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 24-41-34-000-001 | Removal of the Ground Power Control Unit (GPCU) |
| AMM 24-41-34-400-001 | Installation of the Ground Power Control Unit (GPCU) |
Subtask 24-23-00-869-061-A ** ON A/C NOT FOR ALL
A. Test
Not applicable.
4. Fault IsolationNot applicable.
NOTE: As the APU GEN was set to OFF because of a true failure, the fault confirmation is not necessary.
Subtask 24-23-00-810-075-A ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the CFDS message GEN APU (8XS)/ GAPCU (24XG)/ WRG: GEN APU FEEDER and the upper ECAM-DU warning APU GEN FAULT:
Subtask 24-23-00-860-063-A ** ON A/C NOT FOR ALL - do a check of the resistance of the neutral-to-phase connections ASM 242301 of the APU generator between:
. terminal T1 and N (9.35 milliohms plus or minus 1.25 milliohms)
. terminal T2 and N (9.35 milliohms plus or minus 1.25 milliohms)
. terminal T3 and N (9.35 milliohms plus or minus 1.25 milliohms).
- replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
- do a check of the wiring of the APU generator neutral-feeder for an open circuit or a high resistance between the terminal N of the APU generator and the airframe ground ASM 242301.
- repair or replace the neutral feeder as necessary.
- replace the GAPCU [24XG] AMM 24-41-34-000-001 and AMM 24-41-34-400-001.
- replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
B. Make sure that the aircraft electrical circuits operate correctly in APU configuration.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) Let the APU generator operate for five minutes.
(3) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) Let the APU generator operate for five minutes.
(3) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.