Failure of the Neutral-To-Phase System of the APU Generator or the Neutral Feeder


TASK 24-23-00-810-819-A
Failure of the Neutral-To-Phase System of the APU Generator or the Neutral Feeder


1. Possible Causes
  • wiring
  • GEN-APU [8XS]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 242301
AMM 24-23-51-000-001
Removal of the APU Generator
AMM 24-23-51-400-001
Installation of the APU Generator
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
3. Fault Confirmation
Subtask 24-23-00-869-055-A ** ON A/C NOT FOR ALL
A. Test
Not applicable.
NOTE: As the APU GEN was set to OFF because of a true failure, the fault confirmation is not necessary.
4. Fault Isolation
Subtask 24-23-00-810-064-B ** ON A/C NOT FOR ALL
A. If the fault symptom is identified by the CFDS message WRG: FEEDER NEUTRAL/ GEN APU (8XS) and the upper ECAM-DU warning APU GEN FAULT:
  • do a check of the wiring of the APU generator neutral-feeder for an open circuit or a high resistance condition between the terminal N of the APU generator and the airframe ground ASM 242301.
   (1) If the wiring is not correct:
  • repair or replace the neutral feeder as necessary.
   (2) If the wiring is correct:
  • do a check of the resistance of the neutral-to-phase connections ASM 242301 of the APU generator between:
    . terminal T1 and N (9.35 milliohms plus or minus 1.25 milliohms)
    . terminal T2 and N (9.35 milliohms plus or minus 1.25 milliohms)
    . terminal T3 and N (9.35 milliohms plus or minus 1.25 milliohms).
     (a) If the resistance values are out of the specified limits:
     (b) If the resistance values are in the specified limits and the fault continues:
Subtask 24-23-00-860-057-A ** ON A/C NOT FOR ALL
B. Make sure that the aircraft electrical circuits operate correctly in APU configuration.
   (1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
   (2) Let the APU generator operate for five minutes to make sure that it operates correctly.
   (3) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.