Failure of the APU Generator PMG-Stator or its Wiring to the GAPCU
TASK 24-23-00-810-815-A
Failure of the APU Generator PMG-Stator or its Wiring to the GAPCU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-23-00-869-054-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:40 UTC
Failure of the APU Generator PMG-Stator or its Wiring to the GAPCU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242301 | |
| AMM 24-23-51-000-001 | Removal of the APU Generator |
| AMM 24-23-51-400-001 | Installation of the APU Generator |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 24-41-34-000-001 | Removal of the Ground Power Control Unit (GPCU) |
| AMM 24-41-34-400-001 | Installation of the Ground Power Control Unit (GPCU) |
Subtask 24-23-00-869-054-A ** ON A/C NOT FOR ALL
A. Test
Not applicable.
4. Fault IsolationNot applicable.
NOTE: As the APU GEN was set to OFF because of a true failure, the fault confirmation is not necessary.
CAUTION:
BEFORE YOU START THE CHECK OF IDG WIRING THAT INCLUDES CONNECTORS, EXAMINE EACH CONNECTOR TO MAKE SURE THAT THERE IS NO CONTAMINATION IN IT.
IF YOU FIND CONTAMINATION, CLEAN THE CONNECTOR AND CONNECT IT AGAIN.
IF THE FAILURE CONTINUES, DO THE TROUBLE SHOOTING PROCEDURE AS GIVEN BELOW.
Subtask 24-23-00-810-061-B ** ON A/C NOT FOR ALL A. If the fault symptom is identified by the CFDS message GEN APU (8XS) PMG/ GAPCU (24XG):
(1) If the CFDS message comes into view with the fault codes 122, 182, 197 or 199:
Subtask 24-23-00-860-056-A ** ON A/C NOT FOR ALL (1) If the CFDS message comes into view with the fault codes 122, 182, 197 or 199:
- do a check of the resistance of the APU generator PMG-stator ASM 242301 between:
. pins A/12 and A/13 of the APU generator (0.868 ohm plus or minus 0.156 ohm)
. pins A/12 and A/14 of the APU generator (0.868 ohm plus or minus 0.156 ohm)
. pins A/13 and A/14 of the APU generator (0.868 ohm plus or minus 0.156 ohm).
- replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
- do a check of the wiring ASM 242301 for a short to ground, a short circuit or an open circuit between:
. pin A/12 of the APU generator and pin C/10 of the GAPCU
. pin A/13 of the APU generator and pin C/11 of the GAPCU
. pin A/14 of the APU generator and pin C/9 of the GAPCU
. pins C/9, C/10, C/11 and pin C/7 of the GAPCU.
- repair or replace as necessary.
- replace the GAPCU [24XG] AMM 24-41-34-000-001 and AMM 24-41-34-400-001.
- replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
- replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
- do a check of the wiring ASM 242301 for a short to ground, a short circuit or an open circuit between:
. pin A/12 of the APU generator and pin C/10 of the GAPCU
. pin A/13 of the APU generator and pin C/11 of the GAPCU
. pin A/14 of the APU generator and pin C/9 of the GAPCU
. pins C/9, C/10, C/11 and pin C/7 of the GAPCU.
- repair or replace as necessary.
- replace the GAPCU [24XG] AMM 24-41-34-000-001 and AMM 24-41-34-400-001.
B. Make sure that the aircraft electrical circuits operate correctly in APU configuration.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) Let the APU generator operate for five minutes to make sure that it operates correctly.
(3) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) Let the APU generator operate for five minutes to make sure that it operates correctly.
(3) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.