Failure of the APU Generator Exciter-Field or its Wiring
TASK 24-23-00-810-813-A
Failure of the APU Generator Exciter-Field or its Wiring
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-23-00-869-052-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:40 UTC
Failure of the APU Generator Exciter-Field or its Wiring
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242301 | |
| AMM 24-23-51-000-001 | Removal of the APU Generator |
| AMM 24-23-51-400-001 | Installation of the APU Generator |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 24-41-34-000-001 | Removal of the Ground Power Control Unit (GPCU) |
| AMM 24-41-34-400-001 | Installation of the Ground Power Control Unit (GPCU) |
| AMM 49-91-41-200-002 | Remove and Discard Oil Filter Elements (131-9(A)) |
| AMM 49-91-41-920-001 | Discard Pressure Oil Filter Element (APS 3200) |
| AMM 49-91-45-200-002 | Discard Lube and Alternator Scavenge Filter Elements (GTCP 36-300) |
| AMM 49-91-45-200-003 | Remove and discard Lube Filter and Generator Scavenge Filter Elements (GTCP 36-300) |
Subtask 24-23-00-869-052-A ** ON A/C NOT FOR ALL
A. Test
Not applicable.
4. Fault IsolationNot applicable.
NOTE: As the APU GEN was set to OFF because of a true failure, the fault confirmation is not necessary.
CAUTION:
BEFORE YOU START THE CHECK OF IDG WIRING THAT INCLUDES CONNECTORS, EXAMINE EACH CONNECTOR TO MAKE SURE THAT THERE IS NO CONTAMINATION IN IT.
IF YOU FIND CONTAMINATION, CLEAN THE CONNECTOR AND CONNECT IT AGAIN.
IF THE FAILURE CONTINUES, DO THE TROUBLE SHOOTING PROCEDURE AS GIVEN BELOW.
Subtask 24-23-00-810-059-A ** ON A/C NOT FOR ALL A. If the fault symptom is identified by the CFDS message GEN APU (8XS) EX FLD/ GAPCU (24XG) and the upper ECAM-DU warning APU GEN FAULT:
Subtask 24-23-00-860-054-A ** ON A/C NOT FOR ALL - Do the check of the resistance of the APU generator exciter-field ASM 242301 between:
. pins A/9 and A/10 of the APU generator (7.67 ohms plus or minus 0.73 ohms) - do a check of the wiring for a short-circuit between:
. pin A/9 of the APU generator and APU generator case
. pin A/10 of the APU generator and APU generator case.
NOTE: Do the check:
(1) If the resistance values are out of the specified limits:- GTCP 36-300: for metal contamination of the lube filter element and the generator scavenge filter element AMM 49-91-45-200-002 or AMM 49-91-45-200-003.
or - APS 3200: for metal contamination of the pressure oil filter element AMM 49-91-41-920-001 and the AC-generator scavenge filter element AMM 49-91-41-200-002.
or - 131-9(A): for metal contamination of the oil filters AMM 49-91-41-200-002.
- Replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
- Do a check of the wiring ASM 242301 for a short to ground, a short circuit or an open circuit between:
. pin A/9 of the APU generator and pin C/12 of the GAPCU
. pin A/10 of the APU generator and pin C/13 of the GAPCU
. pin C/7 and pins C/12, C/13 of the GAPCU.
- Repair or replace as necessary.
- Replace the GAPCU [24XG] AMM 24-41-34-000-001 and AMM 24-41-34-400-001.
- Replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001
B. Make sure that the aircraft electrical circuits operate correctly in APU configuration.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) Let the APU generator operate for five minutes to make sure that it operates correctly.
(3) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.
(1) Energize the aircraft electrical circuits from the APU AMM 24-41-00-861-002.
(2) Let the APU generator operate for five minutes to make sure that it operates correctly.
(3) De-energize the aircraft electrical circuits from the APU AMM 24-41-00-862-002.