W DOC AIRBUS | TSM A320F

Failure of the APU GEN found by the ECB


TASK 24-23-00-810-803-A
Failure of the APU GEN found by the ECB


1. Possible Causes
  • C/B-APU GEN/EGIU2/115VAC [23XS]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 24-00-00-810-803-A
Circuit Breaker Tripped and/or C/B TRIPPED Warning
ASM 242301
AMM 49-00-00-710-001
Self-Test of the ECB
AMM 49-00-00-710-005
Self-Test of the ECB
ASM 496101
3. Fault Confirmation
Subtask 24-23-00-710-053-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the self test of the ECB:
4. Fault Isolation
Subtask 24-23-00-865-050-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
123VUAPU GEN/EGIU2/115VAC23XSAA08
Subtask 24-23-00-810-052-B ** ON A/C NOT FOR ALL
B. If the test gives the CLASS 3 maintenance message GENERATOR 8XS or the CLASS 2 maintenance message ECB (59KD):
  • Do a check of the status of the circuit breaker APU GEN/EGIU2/115VAC (23XS).
   (1) If the circuit breaker is open:
     (a) If the fault continues:
  • Replace the C/B-APU GEN/EGIU2/115VAC [23XS] .
   (2) If the circuit breaker is closed:
  • Do a check and repair the wiring between:
    . the circuit breaker APU GEN/EGIU2/115VAC (23XS) and the pin AC/8 of the ECB (59KD) ASM 496101.
    . the circuit breaker APU GEN/EGIU2/115VAC (23XS) and the pin A/D of the APU GLC (3XS) ASM 242301.
Subtask 24-23-00-810-052-C ** ON A/C NOT FOR ALL
B. If the test gives the CLASS 3 maintenance message GENERATOR 8XS or the CLASS 2 maintenance message ECB (59KD):
  • Do a check of the status of the circuit breaker APU GEN/EGIU2/115VAC (23XS).
   (1) If the circuit breaker is open:
     (a) If the fault continues:
  • Replace the C/B-APU GEN/EGIU2/115VAC [23XS] .
   (2) If the circuit breaker is closed:
  • Do a check and repair the wiring between:
    . the circuit breaker APU GEN/EGIU2/115VAC (23XS) and the pin AC/8 of the ECB (59KD) ASM 496101
    . the circuit breaker APU GEN/EGIU2/115VAC (23XS) and the pin 9 of the APU/EXT power contactor module (29XN) ASM 242301.
Subtask 24-23-00-710-054-A ** ON A/C NOT FOR ALL
C. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:26:39 UTC