Failure of the APU GEN found by the ECB
TASK 24-23-00-810-803-A
Failure of the APU GEN found by the ECB
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 24-23-00-710-053-A ** ON A/C NOT FOR ALL
Subtask 24-23-00-865-050-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:26:39 UTC
Failure of the APU GEN found by the ECB
1. Possible Causes
- C/B-APU GEN/EGIU2/115VAC [23XS]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-00-00-810-803-A | Circuit Breaker Tripped and/or C/B TRIPPED Warning |
| ASM 242301 | |
| AMM 49-00-00-710-001 | Self-Test of the ECB |
| AMM 49-00-00-710-005 | Self-Test of the ECB |
| ASM 496101 |
Subtask 24-23-00-710-053-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the self test of the ECB:
4. Fault Isolation(1) Do the self test of the ECB:
- GTCP 36-300 AMM 49-00-00-710-001
or - APS 3200 AMM 49-00-00-710-005.
Subtask 24-23-00-865-050-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 24-23-00-810-052-B ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 123VU | APU GEN/EGIU2/115VAC | 23XS | AA08 |
B. If the test gives the CLASS 3 maintenance message GENERATOR 8XS or the CLASS 2 maintenance message ECB (59KD):
Subtask 24-23-00-810-052-C ** ON A/C NOT FOR ALL - Do a check of the status of the circuit breaker APU GEN/EGIU2/115VAC (23XS).
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace the C/B-APU GEN/EGIU2/115VAC [23XS] .
- Do a check and repair the wiring between:
. the circuit breaker APU GEN/EGIU2/115VAC (23XS) and the pin AC/8 of the ECB (59KD) ASM 496101.
. the circuit breaker APU GEN/EGIU2/115VAC (23XS) and the pin A/D of the APU GLC (3XS) ASM 242301.
B. If the test gives the CLASS 3 maintenance message GENERATOR 8XS or the CLASS 2 maintenance message ECB (59KD):
Subtask 24-23-00-710-054-A ** ON A/C NOT FOR ALL - Do a check of the status of the circuit breaker APU GEN/EGIU2/115VAC (23XS).
- Do the procedure (Ref. TSM TASK 24-00-00-810-803).
- Replace the C/B-APU GEN/EGIU2/115VAC [23XS] .
- Do a check and repair the wiring between:
. the circuit breaker APU GEN/EGIU2/115VAC (23XS) and the pin AC/8 of the ECB (59KD) ASM 496101
. the circuit breaker APU GEN/EGIU2/115VAC (23XS) and the pin 9 of the APU/EXT power contactor module (29XN) ASM 242301.
C. Do the test given in Para. 3.