Difference in Current between the APU GEN Current Transformer and the APU AC Current Transformer
TASK 24-23-00-810-802-A
Difference in Current between the APU GEN Current Transformer and the APU AC Current Transformer
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 24-23-00-710-051-A ** ON A/C NOT FOR ALL 4. Fault Isolation
[Rev.8 from Aug 2018]
2026.04.04 04:26:39 UTC
Difference in Current between the APU GEN Current Transformer and the APU AC Current Transformer
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 242301 | |
| AMM 24-23-17-000-001 | Removal of the AC Current Transformer |
| AMM 24-23-17-400-001 | Installation of the AC Current Transformer |
| AMM 24-23-34-000-001 | Removal of the GCU-APU |
| AMM 24-23-34-400-001 | Installation of the GCU-APU |
| AMM 24-23-51-000-001 | Removal of the APU Generator |
| AMM 24-23-51-400-001 | Installation of the APU Generator |
| AMM 24-41-00-740-004 | Operational Check of the GPCU via the CFDS |
Subtask 24-23-00-710-051-A ** ON A/C NOT FOR ALL 4. Fault Isolation
CAUTION:
BEFORE YOU START THE CHECK OF IDG WIRING THAT INCLUDES CONNECTORS, EXAMINE EACH CONNECTOR TO MAKE SURE THAT THERE IS NO CONTAMINATION IN IT.
IF YOU FIND CONTAMINATION, CLEAN THE CONNECTOR AND CONNECT IT AGAIN.
IF THE FAILURE CONTINUES, DO THE TROUBLE SHOOTING PROCEDURE AS GIVEN BELOW.
Subtask 24-23-00-810-051-A ** ON A/C NOT FOR ALL A. If this test gives the maintenance message CHECK GCU APU PIN B11D, B13D:
c Install the APU GCU (1XS) AMM 24-23-34-400-001.
(2) If the insulation check is not correct:
3 Install the APU GCU (1XS) AMM 24-23-34-400-001.
Subtask 24-23-00-710-052-A ** ON A/C NOT FOR ALL - Remove the APU GCU (1XS) AMM 24-23-34-000-001.
- On the connector AB of the APU GCU (1XS), connect together the pins AB/13A to AB/13D ASM 242301.
- Do an insulation check between the pins AB/13A to AB/13D of the connector AB of the APU GCU (1XS) and the ground.
- On the connector AB of the APU GCU (1XS), disconnect the pins AB/13A to AB/13D and connect together the pins AB/11A to AB/11D ASM 242301.
- Do an insulation check between the pins AB/11A to AB/11D and the ground.
- Replace the GCU-APU [1XS] AMM 24-23-34-400-001.
- Disconnect the connector A of the APU-generator AC current-transformer (42XS).
- Connect together the pins A/1 to A/4 of the APU-generator AC current-transformer (42XS) ASM 242301.
- Do an insulation check between the pins A/1 to A/4 of the APU-generator AC current-transformer (42XS) and the ground.
- Replace the CT-AC, APU GEN [42XS] AMM 24-23-17-000-001 and AMM 24-23-17-400-001.
- On the connector AB of the APU GCU (1XS), disconnect the pins AB/11A to AB/11D ASM 242301.
- The ground and, in sequence, the pins AB/11A to AB/11D of the connector AB of the APU GCU (1XS) and repair the wiring .
c Install the APU GCU (1XS) AMM 24-23-34-400-001.
(2) If the insulation check is not correct:
- Disconnect the connector A of the APU generator (8XS).
- On the APU generator (8XS), connect together the pins A/1 and A/6 to A/8 ASM 242301.
- Do an insulation check between the pins A/1, A/6 to A/8 and the ground.
- Replace the GEN-APU [8XS] AMM 24-23-51-000-001 and AMM 24-23-51-400-001.
- Disconnect the pins AB/13A to AB/13D of the APU GCU (1XS) ASM 242301.
- The ground and, in sequence, the pins AB/13A, AB/13B, AB/13C, AB/13D and repair the wiring .
3 Install the APU GCU (1XS) AMM 24-23-34-400-001.
B. After the subsequent flight, make sure that the fault does not continue.